DIN Rail Power Supply

CliQ M

24V 960W / DRM-24V960W1PN

Highlights & Features

  • Universal AC input voltage range
  • Built-in active PFC with up to 95.5% efficiency
  • Full power from -25°C to +60°C @ 5,000m (16,400 ft.)
  • Power Boost of 150% up to 7 seconds
  • Advanced Power Boost (APB) – protect system and ensure continuing operation when large inrush current detected due to faulty load on a multiple load connection
  • DNV GL and ABS approvals for maritime applications
  • Built-in DC OK Contact and LED indicator for DC OK/ Overload
  • Features current sharing for parallel connection / Shut-Down Input / Remote Control of Output Voltage / Internal Data Logging for troubleshooting
  • Conformal coating on PCBAs to protect against common dust and chemical pollutants
Dimensions (L x W x D) : 
124 x 125 x 133.6 mm
4.88" x 4.92" x 5.26"
Unit Weight : 
2.87 kg (6.33 lb)
Nominal Output Voltage
24V
Output Voltage Adjustment Range
24-28Vdc
Output Current
40A
Output Power
960W
Line Regulation
10mV Max. (@ 85-264Vac input, 100% load)
Load Regulation
50mV Max. (@ single mode, 0-100% load)
1000mV Typ. (@ parallel mode, 0-100% load)
PARD (20MHz)
100mVpp Max.
Start-up Time
800ms Max. (24V, 40A.) @ 100Vac, 120Vac, 230Vac
Hold-up Time
24ms typ. (24V, 40A.) @ 100, 120, 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% Max. @ 0.7-40A load Slew rate 0.1A/µs (@ 5Hz, 50Hz & 1kHz, 50% Duty Cycle)
Start-up with Capacitive Loads
40,000µF Max.
Parallel Connection
Yes
Series Connection
Yes
Rise Time
75ms Max.(40,000µF, 24V, 40A.) @ 100Vac, 120Vac, 230Vac
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac (Continuously operating)
85-90Vac (With power de-rating)
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
10.50A Typ. @ 100Vac, 8.60A Typ. @ 120Vac, 4.50A Typ. @ 230Vac
Efficiency at 100% load
94.10% Typ. @ 100Vac, 94.71% Typ. @ 120Vac, 95.98% Typ. @ 230Vac
Max Inrush Current
(Cold Start)
8A Typ. @ 100Vac, 10A Typ. @ 120Vac, 17A Typ. @ 230Vac, 11A Max. @ 100Vac, 13A Max. @ 120Vac, 20A Max. @ 230Vac
Power Factor at 100% load
0.99 Typ. @ 100Vac, 0.99 Typ. @ 120Vac, 0.96 Typ. @ 230Vac
Leakage Current
(Enclosure to Neutral)
0.50mA / 1.21mA : 110Vac, 50Hz, TN/TT system / IT system
0.71mA / 1.73mA : 132Vac, 50Hz, TN/TT system / IT system
1.18mA / 2.82mA : 264Vac, 50Hz, TN/TT system / IT system
Max Power Dissipation
At 24V,0A: 5.58W Typ. @ 100Vac, 4.61W Typ. @ 120Vac, 3.70W Typ. @ 230Vac, 13.90W Max. @ 100Vac, 13.10W Max. @ 120Vac, 13.20W Max. @ 230Vac
At 24V,40A: 60.32W Typ. @ 100Vac, 53.71W Typ. @ 120Vac, 40.21W Typ. @ 230Vac, 70.00W Max. @ 100Vac, 65.60W Max. @ 120Vac, 54.80W Max. @ 230Vac
Case Chassis / Cover
Aluminium
Dimensions
124 x 125 x 133.6 mm
4.88" x 4.92" x 5.26"
Unit Weight
2.87 kg (6.33 lb)
Indicator
Green LED (DC OK) and Red LED (Overload)
Cooling System
Convection
Operating Temperature
-25°C to +70°C (Cold start -40°C)
Storage Temperature
-40°C to +85°C
Power De-rating
Vertical Mounting:
Temperature: > 60°C de-rate power by 2.5% / °C
Input Voltage: If < 90Vac, > 55°C de-rate power by 1.67% / °C
Horizontal Mounting:
Temperature: > 40°C de-rate power by 1.67% / °C
Input Voltage: If < 90Vac, > 35°C de-rate p
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
Vibration Test (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
0 to 2,500 Meters (8,200 ft.) for IEC/EN 61558
Pollution Degree
2
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Over Voltage Category
III : According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
Overvoltage
< 32V, SELV Output, Hiccup Mode, Non-Latching (Auto- Recovery)
Overload / Overcurrent
> 150% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of Protection
IP20
Protection Against Shock
Class I with Primary Earth connection
MTBF
MTBF (as per Telcordia SR-332) :
513,800 hrs. I/P: 100Vac, O/P: 24V, 40A, Ta: 25°C
312,900 hrs. I/P: 100Vac, O/P: 24V, 40A, Ta: 40°C
Expected Cap Life Time
131,400hrs. O/P: 24V, 40A, Ta: 25°C
131,400hrs. O/P: 24V, 20A, Ta: 25°C
60,000hrs. @ 100Vac, 92,000hrs. @ 230Vac O/P: 24V, 40A, Ta: 40°C
131,400hrs.@ 100Vac, 115,400hrs. @ 230Vac O/P: 24V, 20A, Ta: 40°C
Electrical Safety
SIQ Bauart: EN 60950-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)
CB scheme: IEC 60950-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic Isolation
4.54KVac: Input / Output
2.5KVac: Input / PE
4.54KVac: Input / DC OK relay contact
1.5KVac: Output / PE
0.5KVac: Output / DC OK relay contact
1.5KVac: DC OK relay contact / PE
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
CSA: CSA C22.2 No. 107.1-01 (File No. 181564)
Electrical Equipments of Machines
EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power Installations
IEC/EN 62477-1 / IEC 62103
Safety Entry Low Voltage
PELV (EN 60204-1), SELV (EN 60950-1)
Maritime
DNV GL: Germanischer Lloyd classified
ABS: American Bureau for Shipping) PDA Environmental category: C, EMC2
Material and Parts
RoHS Directive 2011/65/EU Compliant (EN 50581)
Isolation Resistance
> 5MOhm: Input to Output, 500Vdc
PE Resistance
< 0.1Ohm
Emission
(CE & RE)
Generic Standards: EN 61000-6-3 CISPR 32, EN 55032, CISPR 11, EN 55011, FCC Title 47: Class B
Immunity
Generic Standards: EN 55024, EN 61000-6-2
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
Component Power Supply for General Use
EN 61204-3

Documents

Datasheet Uploaded on 10-Jan-2018 1.4 MB
.DXF Uploaded on 24-Oct-2017 210 KB
Manual Uploaded on 24-Oct-2017 1.7 MB
Mechanical Drawing Uploaded on 24-Oct-2017 134 KB
.STP Uploaded on 24-Oct-2017 4.5 MB
Image Uploaded on 24-Oct-2017 509 KB

Certificates

ABS Uploaded on 24-Oct-2017 818 KB
CB Uploaded on 24-Oct-2017 2.1 MB
CE Uploaded on 24-Oct-2017 47 KB
CSA Uploaded on 24-Oct-2017 43 KB
DNV GL Uploaded on 24-Oct-2017 133 KB
REACH Uploaded on 23-Jul-2018 6.9 MB
RoHS Uploaded on 16-Feb-2018 5.5 MB
SIQ Uploaded on 24-Oct-2017 1.9 MB
UL Uploaded on 24-Oct-2017 68 KB

Related Products

CliQ M 24V 82W

DRM-24V80W1PN

-
Add to Comparison

Output Voltage

24V

Output Current

3.4A

Input Voltage

85-276 Vac

Dimensions

124 x 32 x 102 mm
4.88" x 1.26" x 4.02"

CliQ M 24V 120W

DRM-24V120W1PN

-
Add to Comparison

Output Voltage

24V

Output Current

5A

Input Voltage

85-264 Vac

Dimensions

124 x 40 x 117 mm
4.88" x 1.57" x 4.61"

CliQ M 24V 240W

DRM-24V240W1PN

-
Add to Comparison

Output Voltage

24V

Output Current

10A

Input Voltage

85-276 Vac

Dimensions

124 x 60 x 117 mm
4.88" x 2.36" x 4.61"

CliQ M 24V 480W

DRM-24V480W1PN

-
Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

85-276 Vac

Dimensions

124 x 82 x 127 mm
4.88" x 3.23" x 5.00"