DIN Rail Power Supply

Sync

24V 96W / DRS-24V100W1AZ

Highlights & Features

  • Ultra-compact size and galvanic isolation up to 3.0KVac between input to output and input to ground
  • Universal AC input voltage and full power from -10°C to +55°C operation
  • Up to 89.0% efficiency and built-in active PFC
  • Low earth leakage current < 0.5mA @ 264Vac
  • Built-in DC OK relay contact option available
  • Extreme low temperature cold start at -40°C
  • NEC Class 2 / Limited Power Source (LPS) certified (DRS-24V100W1N☐)


Dimensions (L x W x D) : 
75 x 45 x 100 mm
2.95" x 1.77" x 3.94"
Unit Weight : 
0.325 kg (0.72 lb)
Nominal Output Voltage
24V
Output Voltage Adjustment Range
24-28Vdc
Output Current
4A
Output Power
96W
Line Regulation
< 0.5% (@ 85-264Vac, 100% load)
Load Regulation
< 1.0% (@ 85-264Vac, 0-100% load)
PARD (20mhz)
< 50mVpp @ > 0°C to 70°C
< 100mVpp @ 0°C to -20°C
Start-up Time
< 2,500ms @ 115Vac (100% load)
< 1,500ms @ 230Vac (100% load)
Hold-up Time
> 50ms @ 115Vac & 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz)
Start-up with Capacitive Loads
3,000μF Max
Rise Time
< 100ms @ nominal input (100% load)
Nominal Input Voltage
100-240Vac
Input Voltage Range
85-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
DC Input Voltage Range
120-375Vdc
Input Current
< 1.2A@115Vac, < 0.6A @ 230Vac
Efficiency at 100% load
> 89%@ 115Vac & 230Vac
Max Inrush Current
< 25A @ 115Vac, < 40A@ 230Vac
Power Factor at 100% load
> 0.97 @ 115Vac, > 0.9 @ 230Vac
Leakage Current
< 0.5mA @ 264Vac
Max Power Dissipation
0% load: < 0.4W @ 115Vac & 230Vac
100% load: < 11W @ 115Vac & 230Vac
Case Cover / Chassis
Plastic
Dimensions
75 x 45 x 100 mm
2.95" x 1.77" x 3.94"
Unit Weight
0.325 kg (0.72 lb)
Indicator
Green LED (DC OK)
Cooling System
Convection
Surrounding Air Temperature operating
-20°C to +70°C (Cold start at -40°C@ 40% load)
Surrounding Air Temperature storage
-40°C to +85°C
Power De-rating
-10°C to -20°C de-rate power by 2% / °C
> 55°C de-rate power by 3.33% / °C
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms; 3 times per direction, 9 times in total
Shock (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms; 1 time in X axis
Vibration Test (Non-Operating)
IEC 60068-2-6, Random: 5-500Hz; 2.09Grms, 20 min per axis for all X, Y, Z directions
Vibration (Operation)
IEC 60068-2-6, Sine Wave: 10-500Hz; 2G peak; displacement of 0.35mm; 1 octave per min; 60 min per axis for all X, Y, Z directions
Operating Altitude
0 to 2,000 Meters (6,560 ft.)
Pollution Degree
2
Overvoltage
< 34.8V, SELV Output, Latch Mode
Overload / Overcurrent
105~140% of rated load current, Fold Forward Mode (current rises, voltage drops), Auto-recovery when the fault is removed
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Latch Mode
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
Degree of Protection
IP20
Protection Against Shock
Class I with PE connection
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
121,000 hrs. as per MIL-HDBK-217F
I/P: 115Vac & 230Vac,O/P: 100% load, Ta: 25°C
Expected Cap Life Time
10 years (115ac & 230Vac, 50% load @ 40°C)
Electrical Safety
TUV Bauart: EN 60950-1
UL/cUL recognized: UL 60950-1, CSA C22.2 No. 60950-1 (File No. E191395)
CB Scheme: IEC 60950-1, Limited Power Source (LPS, for DRS-24V100WN☐ only)
CE
In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 3.0 KVac
Output to Ground: 0.5 KVac
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315335)
Safety Entry Low Voltage
SELV (EN 60950)
Material and Parts
RoHS Directive 2011/65/EU Compliant
Emission
Generic Standards: EN 61000-6-3, EN 61000-6-4 CISPR 22, EN 55022 EN 55011, FCC Title 47: Class B
Immunity
Generic Standards: EN 55024, EN 61000-6-1, EN 61000-6-2
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
Component Power Supply for General Use
EN 61204-3

Documents

NEW Datasheet Uploaded on 08-Mar-2016 967 KB
NEW .DXF Uploaded on 08-Mar-2016 174 KB
NEW Manual Uploaded on 08-Mar-2016 2.6 MB
NEW Mechanical Drawing Uploaded on 08-Mar-2016 66 KB
NEW STL Uploaded on 08-Mar-2016 445 KB
NEW Image Uploaded on 08-Mar-2016 453 KB

Certificates

NEW CB Uploaded on 08-Mar-2016 91 KB
NEW CE Uploaded on 08-Mar-2016 97 KB
NEW UL Uploaded on 08-Mar-2016 68 KB
NEW TUV Uploaded on 08-Mar-2016 225 KB

Related Products

Sync 24V 30W

DRS-24V30W1NZ

NEC Class2
Add to Comparison

Output Voltage

24V

Output Current

1.25A

Input Voltage

85-264 Vac

Dimensions

75 x 21 x 89.5 mm
2.95" x 0.83" x 3.52"

Sync 5V 15W

DRS-5V30W1NZ

NEC Class2
Add to Comparison

Output Voltage

5V

Output Current

3A

Input Voltage

85-264 Vac

Dimensions

75 x 21 x 89.5 mm
2.95" x 0.83" x 3.52"

Sync 12V 48W

DRS-12V50W1NZ

Add to Comparison

Output Voltage

12V

Output Current

4A

Input Voltage

85-264 Vac

Dimensions

75 x 30 x 89.5 mm
2.95" x 1.18" x 3.52"

Sync 24V 30W

DRS-24V30W1AZ

-
Add to Comparison

Output Voltage

24V

Output Current

1.25A

Input Voltage

85-264 Vac

Dimensions

75 x 21 x 89.5 mm
2.95" x 0.83" x 3.52"