DRM-24V480W3PN
DIN Rail
CliQ M Serie
DRM-24V480W3PN
Ausgangsspannung
24V
Ausgangsleistung
480W
Ausgangsstrom
20A
Eingangsspannungsbereich
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
Abmessungen
(H x W x D)
124 x 65 x
127.1 mm
4.88” x
2.56” x
5.00”
Gewicht
1.18kg (2.60 lb)
Highlights & technische Merkmale
Built-in constant current circuit for charging application
Full power from -25°C to +60°C @ 5,000m (16,400 ft.)
Power Boost of 150% up to 7 seconds
Advanced Power Boost (APB) – protect system and ensure continuing operation when large inrush current detected due to faulty load on a multiple load connection
DNV GL and ABS approvals for maritime applications
Built-in DC OK Contact and LED indicator for DC OK/ Overload
Conformal coating on PCBAs to protect against common dust and chemical pollutants
Tags
3 phase
Anwendungsbereiche
DRM-24V480W3PN
DRM-24V480W3PN
DIN Rail
CliQ M Serie
DRM-24V480W3PN
Highlights & technische Merkmale
Built-in constant current circuit for charging application
Full power from -25°C to +60°C @ 5,000m (16,400 ft.)
Power Boost of 150% up to 7 seconds
Advanced Power Boost (APB) – protect system and ensure continuing operation when large inrush current detected due to faulty load on a multiple load connection
DNV GL and ABS approvals for maritime applications
Built-in DC OK Contact and LED indicator for DC OK/ Overload
Conformal coating on PCBAs to protect against common dust and chemical pollutants
Ausgangsspannung
24V
Ausgangsleistung
480W
Ausgangsstrom
20A
Eingangsspannungsbereich
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
Dynamische Antwort (Über- & Unterschreiten der Betriebsspannung)
± 5% @ 1.5-100% load
Anlauf mit kapazitiver Last
20,000μF
externe Steuerung (ein/aus)
-
Schutzeinrichtung
-
Spannungsabfall zwischen Eingang und Ausgang
-
Restwelligkeit/ PARD (20MHz)
-
Restwelligkeit
-
Max. Leistgung
-
Welligkeit & Rauschen
-
LED System Spannungsbereich im CC-Modus
-
Einschwingzeit
30ms
Power Boost Dauer
4 seconds Typ. 7 seconds Max.
Power Boost Erholzeit
17 seconds Typ.
Spitzenleistung
-
Nominale Eingangsspannung
3 x 400-500Vac
Eingangsspannungsbereich
3 x 320-575Vac (3-Phase) or 2 x 380-575Vac (2-Phase)
Max. Eingangsspannung
-
Eingangsfrequenz
50-60Hz
Eingangsfrequenz
47-63Hz
DC-Nenneingangsspannung
DC-Eingangsspannungsbereich
450-800Vdc
Eingangsstrom
0.79A @ 24V, 20A
Standby-Leistung
-
Effizienz bei 100 %
95.23% @ 24V, 20A
Einschaltstrom
10.0A
Ladezeit
-
Leistungsfaktor bei 100%
0.93 @ 24V, 20A
Kriechstrom
< 0.80mA / 0.80mA @ 3x400Vac, 50Hz, TN/TT / IT system
Nennstrom
-
Restwelligkeit
-
Leistungsverlust
-
Efficiency @ 10% load
-
Input Voltage Phase
-
Gehäuseausführung
Aluminium
Anzeige
Green LED DC OK Red LED Overload
Kühlsystem
Convection
Eingangsklemme
4 Pins (Rated 600V/35A)
Ausgangsklemme
4 Pins (Rated 300V/30A)
Signalklemme
2 Pins (Rated 300V/28A)
Geräuschschalldruckpegel (SPL)
< 25dBA
Eingangs-/Ausgangsklemme
-
Signal
-
Montageschiene
Standard TS35 DIN Rail in accordance with EN 60715
Leitung
-
Schutz
-
Anschlussklemmen
-
Gewicht
1.18kg (2.60 lb)
Abmessungen
124 x 65 x
127.1 mm 4.88” x
2.56” x
5.00”
Vibration (Betrieb)
-
Stoßtest (Betrieb)
-
Betriebstemperaturbereich
-25°C to +70°C (Cold start -40°C)
Lagertemperatur
-40°C to +85°C
Leistungsbegrenzung
Vertical Mounting: 3-Phase: > 60°C de-rate power by 2.5% / °C 2-Phase: > 60°C de-rate power by 2.5% / °C Horizontal Mounting: 3-Phase: > 40°C de-rate power by 1.67% / °C 2-Phase: > 40°C de-rate power by 2% / °C
Luftfeuchtigkeit Betrieb
5 to 95% RH (Non-Condensing)
Stoßtest (außer Betrieb)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 6 times in total
Vibration (außer Betrieb)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
Luftfeuchtigkeit (Lagerung)
-
Einsatzhöhe
OVC III : 0 to 2,500 Meters (8,200 ft.) OVC II : 2,500 to 6,000 Meters (19,680 ft.), 0 to 5,000 Meters (16,400 ft.), 0 to 3,000 Meters (9,840 ft.)
Verschmutzungsgrad
2
Stoßtest (Betrieb)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Überspannungskategorie
-
Corrosion
-
Shock
-
Vibration
-
Akustisches Rauschen
-
Überspannung
< 32V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Überlast/ Überstrom
160-195% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
Übertemperatur
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Kurzschluss
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Batterieverpolschutz
-
Schutzklasse
IP20
Schutz gegen Schock
Class I with Primary Earth connection
Eingangsverpolschutz
-
Batterieverpolschutz
-
Schutz falsche Batteriespannung
-
Tiefentladungsschutz
-
Überlast
-
Überstrom
-
Integrierte Sicherung
-
Schutz gegen unzureichende Eingangsspannung
-
MTBF
750,000 hrs. as per Telcordia SR-332 I/P: 3 x 400Vac, O/P: 24V, 20A, Ta: 25°C
SIQ Bauart: EN 62368-1, EN 61558-1, EN 61558-2-16, EN 61010-1, EN 61010-2-201 UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme: IEC 60950-1, IEC 62368-1, IEC 61558-1, IEC 61558-2-16, IEC 61010-1, IEC 61010-2-201 UKCA: BS EN 62368-1, BS EN 61558-1, BS EN 61558-2-16, BS EN 61010-1, BS EN 61010-2-201
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Medizinische Unbedenklichkeit
-
Galvanische Trennung
-
Industrielle Steuerungen
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
Gefahrenbereich/ ATEX
-
II 3 G ATEX 2014/34/EU
-
Elektrische Ausrüstung an Maschinen
EN/BS EN 60204-1 (over voltage category III)
Elektrische Ausrüstung zum Einsatz in Stromversorgungsanlagen
IEC/EN/BS EN 62477-1 / IEC 62103
Sicherheit Eingang Niederspannung
SELV (IEC 60950-1)
Maritim
DNV GL: Germanischer Lloyd classified ABS: American Bureau for Shipping) PDA Environmental category: C, EMC2
Material und Teile
-
Isolationswiderstand
> 5MOhm Input to Output, 500Vdc
PE-Widerstand
< 0.1Ohm
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
Certificates for Other Countries
-
BIS
-
KC
-
Electrical Equipment for Measurement, Control, and Laboratory Use
-
ITE Safety
-
SIL3
-
Emission
(CE & RE) Generic Standards: EN/BS EN 61000-6-3 CISPR 32, EN/BS EN 55032, CISPR 11, EN/BS EN 55011, FCC Title 47: Class B
Störfestigkeit
Generic Standards: EN/BS EN 55024, EN/BS EN 55035, EN 61000-6-2
Seien Sie mit der/die erste um über neue Veranstaltungen, Neuigkeiten und Produkte informiert zu werden!
Melden Sie sich jetzt für unseren Newsletter an
Seien Sie mit der/die erste um über neue Veranstaltungen, Neuigkeiten und Produkte informiert zu werden!
Abonnieren
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Datenschutzerklärung.
Marketing Permissions*
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Datenschutzerklärung. Accept