48V
240W
5A
90-264 Vac
123.6 x 40 x 116.8 mm
4.87” x 1.57” x 4.60”
0.64 kg (1.41 lb)
48V
240W
5A
90-264 Vac
123.6 x 40 x 116.8 mm
4.87” x 1.57” x 4.60”
0.64 kg (1.41 lb)
Output Current
5A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
48-55 Vdc
|
Output Power
240W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @ 115 Vac & 230 Vac
|
Load Regulation
± 0.5%
|
PARD
< 150 mVpp @ 0°C to +70°C
< 360 mVpp @ -30°C to 0°C |
Start-up Time
800 ms typ. @ 115 Vac & 230 Vac
|
Hold-up Time
30 ms typ. @ 115 Vac & 230 Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 Vac & 230 Vac input, 10-100% load (Slew Rate: 2.5 A/μS, 50% duty cycle @ 5 Hz & 10 kHz)
|
Start-up with Capacitive Loads
5,000 µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30 ms typ. @ 115 Vac & 230 Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.5 A typ. @ 115 Vac, 1.3 A typ. @ 230 Vac
|
Input Power (Standby Mode)
0.8 W max @ 115 Vac & 230 Vac
|
Efficiency at 100% load
94.0% typ. @ 230 Vac
|
Max Inrush Current
40 A typ. @ 230 Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.96 @ 115 Vac & > 0.93 @ 230 Vac
|
Leakage Current
< 0.5 mA @ 240 Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Metal
|
|
Indicator
Green LED DC OK
|
|
Cooling System
Convection
|
|
Input Terminal
3 Pins (Rated 600 V / 30 A)
|
|
Output Terminal
4 Pins (Rated 600 V / 30 A)
|
|
Signal Terminal
2 Pins (Rated 300 V / 6 A)
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input: AWG 18-12
Output: AWG 18-12 DC OK: AWG 22-16 |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.64 kg (1.41 lb)
|
Dimensions
123.6 x 40 x
116.8 mm
4.87” x 1.57” x 4.60” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10 Hz to 500 Hz; 4 G peak; 60 min per axis for all X, Y, Z directions
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Temperature: > 60°C de-rate power by 2.5 % / °C
Input Voltage: < 100 Vac de-rate power by 1% / Vac |
Operating Humidity
5 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50 G for duration of 11 ms; 3 times per direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Corrosion
-
|
Overvoltage
<68 V, SELV Output, Latch Mode
|
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode (Vo > 80%) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T4 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
Telcordia SR-332: > 700,000 hrs
I/P: 115 Vac & 230 Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (115 Vac & 230 Vac, 50% load @ 50°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1/-2-201
TUV Bauart: EN/BS EN 62368-1, EN/BS EN 61010-1/-2-201 UL/cUL: UL 62368-1, UL 61010-1/-2-201 EAC: TP TC 004/2011 BSMI: CNS14336-1 CCC: GB4943.1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 4.0 kVac
Input to Ground: 2.0 kVac Output to Ground: 1.5 kVac Output to DC OK: 500 Vac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR 32, EN/BS EN 61204-3, KS C 9832 Compliance to FCC Title 47, EN 61000-6-3: Class B |
Immunity
EN/BS EN 55035, KS C 9835, EN/BS EN 61000-6-2 Compliance to EN 61000-6-1
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A & Class D
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
24V
480W
20A
90-264 Vac
24V
480W
20A
90-264 Vac
24V
960W
40A
3 x 320-575 Vac
48V
480W
10A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.