Click the link below to download the file.
Get your files as below link
Dowload link
18V
120W
6.67A
90-264 Vac
76.2 x 50.8 x 31 mm
3.00” x 2.00” x 1.22”
0.14 kg (0.31 lb)
18V
120W
6.67A
90-264 Vac
76.2 x 50.8 x 31 mm
3.00” x 2.00” x 1.22”
0.14 kg (0.31 lb)
Output Current
6.67A
|
Output Voltage
18V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
120W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
0.5%
|
Load Regulation
1%
|
PARD
150 mVpp @≥ 25 °C
450 mVpp @ ≥ -30 °C |
Start-up Time
1000 ms @ 115 Vac
500 ms @ 230 Vac |
Hold-up Time
20 ms @ 100% load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ with 5-100% load change, (50% duty @ 5 Hz & 10 KHz, 2.5 A/us slew rate )
|
Start-up with Capacitive Loads
8000 uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
150 W
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
40 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.3 A @ 115 Vac
0.9 A @ 230 Vac |
Input Power (Standby Mode)
< 0.21 W @ 115 Vac & 230 Vac
|
Efficiency at 100% load
92.0% @ 115 Vac
94.0% @ 230 Vac |
Max Inrush Current
60 A @ 230 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.98 @ 115 V/60 Hz, full load
|
Leakage Current
0.1 mA @ NC, 1.0 mA @ SFC
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Open Frame
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
JST, B2P3-VH(LF)(SN) or equivalent
|
|
Output Terminal
JST : B4P-VH(LF)(SN) or equivalent
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25 dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.14 kg (0.31 lb)
|
Dimensions
76.2 x 50.8 x
31 mm
3.00” x 2.00” x 1.22” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-30°C to +70°C (-40°C cold start )
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Temperature Power De-rating: Linear power derating from 100% load at 50°C to 50% load at 70°C with 2.5%/°C
Line Power De-rating: < 120Vac de-rate power by 0.83% / Vac |
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa) ( 4000 meters for IEC 60335-1, IEC 61558-1 )
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Corrosion
-
|
Overvoltage
Main output 110-150% of rated normal voltage, Latch mode
|
Overload / Overcurrent
Main output 105-185% of rated current , Hiccup Mode
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I & II
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
Home Appliance
IEC60335-1 CB report IEC61558-1 /-2-16 CB report TUV EN60335-1 TUV EN61558-1/-2-16 |
Electrical Safety
-
|
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
IEC60601-1 3rd+A1 edition CB report
TUV EN60601-1:2006 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1:14 |
Galvanic Isolation
Input to/Output (2XMOPP: 4000 Vac
Input to/Ground(1XMOPP): 2000 Vac Output to/Ground(1XMOPP): 1500 Vac ( Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 Regulations 2016 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC60950-1 CB report
IEC62368-1 CB report (Ed.2-2014 & Ed.3-2018) TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 |
SIL3
-
|
Emission
EN55032, CISPR 32 AS/NZS CISPR32 & CISPR11 Class B Compliance to EN55014-1, CISPR 14-1, AS/NZS CISPR 14 Class B
Note: Class A Radiated Emission for Class II connection without earth connection |
Immunity
-
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class A limit
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
15V
120W
8A
90-264 Vac
12V
200W
-
90-264 Vac
24V
120W
5A
90-264 Vac
12V
114W
9.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.