Click the link below to download the file.
Get your files as below link
Dowload link
36V
300W
8.3A
90-264Vac
127 x 76.2 x 35.8 mm
5.00” x 3.00” x 1.41”
0.45 kg (0.99 lb)
36V
300W
8.3A
90-264Vac
127 x 76.2 x 35.8 mm
5.00” x 3.00” x 1.41”
0.45 kg (0.99 lb)
Output Current
8.3A
|
Output Voltage
36V
|
Output Voltage Range
|
Output Voltage Adjustment Range
34.2-37.8Vdc
|
Output Power
300W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
V1 and VSB: < 0.5% (@ 90-264Vac input, 0-100% load)
|
Load Regulation
V1 and VSB: < 1.0% (@ 90-264Vac input, 0-100% load)
|
PARD
V1: < 240mVpp
VSB: < 120mVpp |
Start-up Time
< 1,200ms @ nominal input (100% load)
|
Hold-up Time
> 12ms @ 115Vac & 230Vac (240W)
> 10ms @ 115Vac & 230Vac (300W) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 90-264Vac input, V1: 10-100% load, VSB: 0-100%
(Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz, 50Hz, 1KHz) |
Start-up with Capacitive Loads
8,000μF Max @ nominal input (100% load)
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 100ms @ nominal input (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 4.0A @ 115Vac, < 2.0A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 93% @ 115Vac
> 94% @ 230Vac |
Max Inrush Current
< 20A @ 115Vac, < 40A @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 115Vac & 230Vac
|
Leakage Current
< 0.75mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
100% Load: < 23W @ 115Vac & 230Vac
|
Case Chassis / Cover
-
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection, Fan Cool
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.45 kg (0.99 lb)
|
Dimensions
127 x 76.2 x
35.8 mm
5.00” x 3.00” x 1.41” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-25°C to +70°C (Cold Start -40°C)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine 30G for a duration of 18ms, 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); displacement of 0.35mm; 60 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
PD2: 0 to 3,000 Meters (9,840 ft.), Class II
PD3: 0 to 5,000 Meters (16,400 ft.), Class I |
Pollution Degree
PD2, PD3
|
Bump Test (Operating)
IEC 60068-2-29, Half Sine 10G (100m/S²) for a duration of 11ms,
1,000 times per direction, 6,000 times in total |
Over Voltage Category
Design to OVC III according to IEC/EN 61558
|
Overvoltage
V1: 39-46.8V, SELV Output, Latch Mode
VSB: 13-15V, SELV Output, Latch Mode |
Overload / Overcurrent
130 ~ 180% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE connection,
Class II without PE connection |
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 80% load or 240W, Ta: 25°C |
Expected Cap Life Time
10 years (115Vac, 40% load or 120W @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 60950-1, EN 62368-1, EN 60335-1, EN 61558-1, EN 61558-2-16
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CB scheme:IEC 60950-1, IEC 62368-1, IEC 60335-1, IEC 61558-1, IEC 61558-2-16 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 4.0KVac
Input to FG: 2.0KVac (PD3, Class I) 4.0kVac (PD2, Class II with Functional Ground) Output to FG: 1.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
> 5MOhm
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Emission
Generic Standards: CISPR 11, CISPR 32, EN/BS EN 55011, EN/BS EN 55032, FCC Title 47, EN 55014-1
|
Immunity
Generic Standards: EN 55024, EN 55035, EN 55014-2, EN 61204-3
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
15V
120W
8A
90-264 Vac
12V
200W
-
90-264 Vac
12V
114W
9.5A
90-264 Vac
12V
600W
-
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.