48V
200W
4.17A
85-305Vac
127.6 x 76.2 x 34.8 mm
5.02” x 3.00” x 1.37”
0.42 kg (0.93 lb)
48V
200W
4.17A
85-305Vac
127.6 x 76.2 x 34.8 mm
5.02” x 3.00” x 1.37”
0.42 kg (0.93 lb)
Output Current
4.17A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
48-50Vdc
|
Output Power
200W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1% typ. (@ 100-277Vac input, 100% load)
|
Load Regulation
± 2% typ. (@ 100-277Vac input, 0-100% load)
|
PARD
< 480mVpp
20MHz, warm up for 10mins |
Start-up Time
< 500ms @ 100Vac & 240Vac (100% load), With and without capacitive loads
|
Hold-up Time
> 5ms @ 115Vac & 230Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 100-305Vac input, 0-50% load & 50-100% load & 0-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz, 50Hz, 1KHz)
|
Start-up with Capacitive Loads
680μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 100ms @ nominal input (100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-277Vac
|
Input Voltage Range
85-305Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 2.20A @ 115Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 85% @ 115Vac, > 90% @ 230Vac
|
Max Inrush Current
< 20A @ 230Vac ((Cold Start))
|
Charging Time
-
|
Power Factor at 100% load
> 0.95 @ 115Vac & 230Vac
|
Leakage Current
< 500μA, According to CSA C22.2 No. 166 and UL8750 edition 2nd
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
No Load: < 0.7W @ 230Vac
100% Load: < 22.2W @ 230Vac |
Case Chassis / Cover
-
|
|
Indicator
NA
|
|
Cooling System
Convection: 0-150W
Fan Cool: 151-200W With 400 LFM fan cool, 15mm distance between PSU and fan |
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
Sound Pressure Level (SPL) < 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.42 kg (0.93 lb)
|
Dimensions
127.6 x 76.2 x
34.8 mm
5.02” x 3.00” x 1.37” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
-
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine 50G for a duration of 11ms, 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 25m/S² (2.5G peak); displacement of 0.35mm; 90 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Overvoltage
< 60V, SELV Output, Latch Mode
|
Overload / Overcurrent
> 105% of rated load current, Hiccup mode, Non-Latching (Auto recovery)
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 500,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 62368-1
cCSAus: CSA C22.2 No. 250.13 and UL 8750 CSA C22.2 No. 60950-1 and UL 60950-1 CSA C22.2 No. 62368-1 and UL 62368-1 CB scheme: IEC 60950-1, IEC 62368-1, IEC 61347-1 and IEC 61347-2-13 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output 4kVac (Reinforced)
3kVac (Production Test) Input to Ground 1.5kVac (Basic & Production Test) Output to Ground 1.5kVac (Basic) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032: Class B
|
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 55035
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class C
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3 at nominal voltages and full load
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
12V
600W
-
90-264 Vac
24V
120W
5A
90-264 Vac
12V
200W
-
90-264 Vac
12V
114W
9.5A
90-264 Vac