Get your files as below link
Dowload link
Get your files as below link
Dowload link
24V
10W
0.42A
90-264Vac
91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
0.065 kg (0.14 lb)
24V
10W
0.42A
90-264Vac
91 x 18 x 55.6 mm
3.58” x 0.71” x 2.19”
0.065 kg (0.14 lb)
Output Current
0.42A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
10W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% (@ 90-264Vac input, 100% load)
|
Load Regulation
< 1.0% (@ 90-264Vac input, 0-100% load)
|
PARD
< 100mVpp
|
Start-up Time
< 2,000ms @ nominal input (100% load)
|
Hold-up Time
> 10ms @ 115Vac,
> 60ms @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 90-264Vac input, 10-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 100Hz) |
Start-up with Capacitive Loads
820μF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 70ms @ nominal input (100% load)
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
125-375Vdc
|
Input Current
< 0.30A @ 115Vac,
< 0.20A @ 230Vac |
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 80.0% @ 115Vac & 230Vac
|
Max Inrush Current
< 15A @ 115Vac,
< 30A @ 230Vac |
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.25mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
0% load: < 0.3W @ 115Vac & 230Vac
100% load: < 2.6W @ 115Vac & 230Vac |
Case Chassis / Cover
Plastic
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
M4 x 2 Pins (Rated 300V/16A)
|
|
Output Terminal
M4 x 2 Pins (Rated 300V/16A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
Input/Output: AWG 24-12
|
|
Protection Structure
-
|
|
Unit Weight
0.065 kg (0.14 lb)
|
Dimensions
91 x 18 x
55.6 mm
3.58” x 0.71” x 2.19” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total
|
Operating Temperature
-25°C to +71°C
|
Storage Temperature
-25°C to +85°C
|
Power De-rating
> 55°C de-rate power by 2.5% /°C
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
0 to 2,000 Meters (6,560 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Overvoltage
Output power < 9W: < 34.8V, SELV Output, Latch Mode
Output power ≥ 9W: < 34.8V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery) |
Overload / Overcurrent
< 15W, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
IP20
|
Protection Against Shock
Class II (No Primary Earth connection is required)
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
MTBF
> 500,000 hrs. as per Telcordia SR-332 (I/P: 100Vac, O/P: 100% load, Ta: 35°C)
|
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart: EN 60950-1, EN 62368-1, EN 60335-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881) CB scheme: IEC 60950-1, IEC 62368-1, IEC 60335-1, Limited Power Source (LPS) |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EC
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (EN 60950)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
-
|
Certificates for Other Countries
UKCA
|
Emission
(CE & RE)
Generic Standards: CISPR 32, EN 55032, FCC Title 47: Class B, EN 55014-1 |
Immunity
Generic Standards: EN 55024, EN 61000-6-2, EN 55014-2
|
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
240W
5A
90-264 Vac
24V
480W
20A
3 x 320-575 Vac
24V
480W
20A
90-264 Vac
24V
960W
40A
3 x 320-575 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.