Click the link below to download the file.
Get your files as below link
Dowload link
12V
120W
10A
90-264Vac
123.6 x 30 x 116.8 mm
4.87” x 1.18” x 4.60”
0.45 kg (0.99 lb)
12V
120W
10A
90-264Vac
123.6 x 30 x 116.8 mm
4.87” x 1.18” x 4.60”
0.45 kg (0.99 lb)
Output Current
10A
|
Output Voltage
12V
|
Output Voltage Range
10.8-13.2Vdc
|
Output Voltage Adjustment Range
10.8-13.2Vdc
|
Output Power
120W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% @ 115Vac & 230Vac
|
Load Regulation
± 1.0%
|
PARD
< 120mVpp @ 0°C to +70°C
< 360mVpp @ -30°C to 0°C |
Start-up Time
500ms typ. @ 115Vac & 230Vac
|
Hold-up Time
10ms typ. @ 115Vac (100% load)
16ms typ. @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
|
Start-up with Capacitive Loads
8,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30ms typ. @ 115Vac & 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
86% typ.@ 230Vac
|
Max Inrush Current
35A typ. @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.5mA @ 240Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminum / SGCC
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
3 Pins (Rated 300V/30A)
|
|
Output Terminal
4 Pins (Rated 300V/20A)
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
Standard TS35 DIN Rail in accordance with EN 60715
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.45 kg (0.99 lb)
|
Dimensions
123.6 x 30 x
116.8 mm
4.87” x 1.18” x 4.60” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 40°C de-rate power by 1.67 % / °C @115Vac
> 50°C de-rate power by 2.5 % / °C @230Vac |
Operating Humidity
20 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Overvoltage
<17.4V, SELV Output, Latch Mode
|
Overload / Overcurrent
105 - 150% of rated load current, Auto-recovery
Continuous current limit Mode*5 (Vo>80%) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with primary earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
T4 A / 250 V
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time
10 years (230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1 & -2-201
TUV Bauart: EN 62368-1, EN 61010-1 & -2-201 UL/cUL: UL 62368-1 CCC: GB4943.1 BSMI: CNS14336-1 EAC: TP TC 004/2011 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3 Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B |
Immunity
EN/BS EN 55035, EN/BS EN 61000-6-2
Compliance to EN/BS EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
IEC 61000-4-2
|
Radiated Immunity
IEC 61000-4-3
|
EFT
IEC 61000-4-4
|
Surge
IEC 61000-4-5
|
Conducted Immunity
IEC 61000-4-6
|
Magnetic Field
IEC 61000-4-8
|
Voltage Dips
IEC 61000-4-11
|
Component Power Supply for General Use
EN/BS EN 61204-3
|
24V
120W
5A
90-264 Vac
24V
960W
40A
3 x 320-575 Vac
48V
240W
5A
90-264 Vac
24V
480W
20A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.