48V
600W
12.5A
100-277Vac
307.5 x 114.3 x 50.8 mm
12.11” x 4.50” x 2.00”
3.15 Kg (6.94 lb)
48V
600W
12.5A
100-277Vac
307.5 x 114.3 x 50.8 mm
12.11” x 4.50” x 2.00”
3.15 Kg (6.94 lb)
Output Current
12.5A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
600W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5%
|
Load Regulation
± 1%
|
PARD
250mV typ (20 MHz)
|
Start-up Time
< 1000ms @ 120Vac
< 500ms @ 230Vac |
Hold-up Time
16ms typ. @ 120Vac & 230Vac & 277Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-90% load, @ 120Vac & 230Vac & 277Vac (Slew Rate: 0.1A/μS)
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
24-48Vdc
|
Rise Time
< 50ms @ 120Vac & 230Vac & 277Vac
|
Nominal Input Voltage
120-240Vac
|
Input Voltage Range
100-277Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
7A max. @ 120Vac, 3.3A max. @ 230Vac, 2.9A max. @ 277Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
96.0% typ. @ 230Vac, 277Vac
|
Max Inrush Current
65A typ. @ 230Vac
|
Charging Time
-
|
Power Factor at 100% load
0.98 typ. @ 120Vac,
0.95 typ. @ 230Vac, 0.93 typ. @ 277Vac |
Leakage Current
< 0.75mA @ 277Vac
|
Nominal Current
-
|
Total Harmonic Distortion
< 20% @ 120Vac/60Hz & 230Vac/50Hz (≥ 50% load)
< 20% @ 277Vac/50Hz (≥ 75% load) |
Max Power Dissipation
< 0.64W @ 230Vac, at 0% load
|
Case Chassis / Cover
Aluminium
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA (1 Meter from power supply)
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Unit Weight
3.15 Kg (6.94 lb)
|
Dimensions
307.5 x 114.3 x
50.8 mm
12.11” x 4.50” x 2.00” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +70°C (Refer to “de-rating curve”)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 120Vac de-rate power by 1.5% / Vac |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 500 Hz (2.09G); 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 3,000 Meters (9,840 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Overvoltage
55.2-67.2V, Latch Mode
|
Overload / Overcurrent
95-108% of rated load current, constant current limit
|
Over Temperature
Latch Mode
|
Short Circuit
Auto-Recovery when the fault is removed Degree of
|
Reverse Polarity Protection
-
|
Degree of Protection
IP67
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332. (I/P: 120Vac, O/P: 100% load, Ta: 25°C)
|
Expected Cap Life Time
7 years (I/P: 120Vac & 230Vac, O/P: 50% load @ Ta = 40°C)
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 61347-1, IEC 61347-2-13
ENEC: EN 61347-1, EN 61347-2-13, EN 62384 UL/cUL recognized: UL 8750 and CAN/CSA C22.2 No.250.13 (Safety approval and dry, damp, wet ratings) |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.3kVac
Input to Ground: 2.0kVac Output to Ground: 1.5kVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
Emission
CISPR 15, EN 55015, Compliance to CISPR 32, EN 55032, FCC Title 47: Class B
|
Immunity
Compliance to EN 61547 and EN55024
|
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
|
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
12V
20W
1.7A
90-305Vac
75-190V
200W
0.6-1.4A
108-305 Vac
8-48V
22W
0.2-1.05A
198-264Vac
12V
30W
0.1-2.5A
90-266Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.