Click the link below to download the file.
Get your files as below link
Dowload link
24V
650W
0-27.1A
90-264 Vac
152.4 x 101.6 x 40 mm
6.00” x 4.00” x 1.57”
0.80 kg (1.76 lb)
24V
650W
0-27.1A
90-264 Vac
152.4 x 101.6 x 40 mm
6.00” x 4.00” x 1.57”
0.80 kg (1.76 lb)
Output Current
0-27.1A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
650W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
1%
|
Load Regulation
2%
|
PARD
-
|
Start-up Time
2000 ms with AC turn on
|
Hold-up Time
20 ms @ 450 W load, with nominal input range
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 0-50% & 50-100% load change
|
Start-up with Capacitive Loads
6000 uF
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
1.0% Vrated pk-pk @ rated load (450 W)
1.5% Vrated pk-pk @ rated load (650 W) |
LED System Voltage Range in CC Mode
-
|
Rise Time
<50 ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240 Vac
|
Input Voltage Range
90-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
8.0 A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
94.5% @ 115 Vac
95.5% @ 230 Vac |
Max Inrush Current
40 A @ 264 Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.95 @ 115 Vac / 50 Hz, 230 Vac / 50 Hz, full load
|
Leakage Current
0.3 mA @ NC, 1 mA @ SFC
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
-
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.80 kg (1.76 lb)
|
Dimensions
152.4 x 101.6 x
40 mm
6.00” x 4.00” x 1.57” |
Vibration (Operating)
5-500 Hz, 2 Grms, 15 minute for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
Convection
Linear power de-rate from 100% load at 50°C, to 53.3% load at 70°C Force Air Linear power de-rate from 100% load at 50°C, to 50% load at 70°C |
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50 G, 11 ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Overvoltage
Main output 140% of rated normal voltage, Latch Mode Standby 125% of rated voltage, Latch Mode
|
Overload / Overcurrent
750 W for over 750 ms max Standby 3.2 A max with Hiccup Mode(Non-Latching, Auto-Recovery)
|
Over Temperature
Latch Mode for Main output
|
Short Circuit
Hiccup Mode for Main output and Standby (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
Safety Certificate
-
|
Electrical Safety
ITE
IEC60950-1 CB report IEC62368-1 CB report TUV EN62368-1 UL62368-1 and CAN/CSA C22.2 No. 62368-1 Household IEC 60335-1 CB report TUV EN 60335-1 IEC 61558-1 CB report |
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
|
Medical Safety
IEC60601-1 2nd and 3rd+A1 edition CB report
TUV EN60601-1:2006 CAN/CSA-C22.2 NO.60601-1 + ANSI/AAMI ES 60601-1 |
Galvanic Isolation
Input to/Output (2 X MOPP): 4000 Vac
Input to/Ground (1 X MOPP) : 1500 Vac Output to/Ground(1 X MOPP) : 1500 Vac ( Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002Regulations 2016 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
48V
650W
-
90-264 Vac
18V
120W
6.67A
90-264 Vac
48V
200W
-
90-264 Vac
12V
114W
9.5A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.