Click the link below to download the file.
Get your files as below link
Dowload link
27.6V
60W
2.15A
90-264Vac
103.4 x 62 x 37 mm
4.07” x 2.44” x 1.46”
0.25 kg (0.55 lb)
27.6V
60W
2.15A
90-264Vac
103.4 x 62 x 37 mm
4.07” x 2.44” x 1.46”
0.25 kg (0.55 lb)
Output Current
2.15A
|
Output Voltage
27.6V
|
Output Voltage Range
|
Output Voltage Adjustment Range
27.04-28.00V
|
Output Power
60W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% (90-264Vac @ 100% load)
|
Load Regulation
< 1.0% (90-264Vac @ 0-100% load)
|
PARD
< 100mVpp
|
Start-up Time
< 3,000ms @ 115Vac (100% load),
< 1,500ms @ 230Vac (100% load) |
Hold-up Time
> 10ms @ 115Vac (100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5%, @ 115-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1kHz)
|
Start-up with Capacitive Loads
3,600μF at 27.6V/2.15A
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms @nominal input
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 1.2A @ 115Vac, < 0.8A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 88.0% @ 115Vac
> 89.0% @ 230Vac |
Max Inrush Current
< 60A @ 115Vac & 230Vac (Cold Start)
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
IEC/EN 60950-1: < 0.5mA / 1.0mA @ 264Vac (TN/TT system / IT system)
IEC/EN 62368-1: < 1.0mA / 2.0mA @ 264Vac (TN/TT system / IT system) |
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
No Load:
< 0.50W @ 115Vac < 0.65W @ 230Vac 100% Load: < 9W @ 115Vac & 230Vac |
Efficiency @ 10% load
-
|
Case Chassis / Cover
SECC
|
|
Indicator
Green LED: DC OK
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 25dBA (1 Meter from power supply)
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.25 kg (0.55 lb)
|
Dimensions
103.4 x 62 x
37 mm
4.07” x 2.44” x 1.46” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 2G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
|
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms; 1 time in X axis
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
See datasheet
|
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms; 3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5-500Hz; 2.09Grms; 20 min per axis for all X, Y, Z directions
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
-
|
Over Voltage Category
II
|
Overvoltage
<34.8V, Latch Mode
|
Overload / Overcurrent
105-160% of rated load current, Hiccup mode, Non-Latching (Auto recovery)
|
Over Temperature
Latch mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
18.0V ± 0.3V
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
Yes
|
Wrong Battery Voltage Protection
Yes, 32Vdc Max will not cause damage to the unit
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, Ta: 25°C O/P: 13.8V/4.3A for 13V model and 27.6V/2.15A for 27V model |
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 35°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) CCC: GB4943.1 CB scheme: IEC 60950-1, IEC 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac Output to Ground: 0.5KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (EN 60950-1, EN 62368-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
Emission
Generic Standards: CISPR 32, EN/BS EN 55032, FCC Title 47: Class B
|
Immunity
Generic Standards: EN/BS EN 55024
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A, GB17625.1
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
Nominal Battery Voltage
24 Vdc
|
Battery Voltage Range
-
|
Battery Capacity
3.2 AH – 7 AH
|
Battery Charging Mode
CC-CV mode (constant current-constant voltage)
|
End of Charge Voltage
The unit always charges battery to a fixed voltage value
|
Battery Fuse
-
|
Battery Discharging Voltage Range
-
|
Battery Charging Current
-
|
Battery Current Consumption
-
|
Discharging Current
-
|
Recommended Charging Voltage
-
|
12V
114W
9.5A
90-264 Vac
15V
120W
8A
90-264 Vac
48V
200W
-
90-264 Vac
18V
120W
6.67A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.