Get your files as below link
Dowload link
Get your files as below link
Dowload link
48V
110W
2.3A
90-264Vac
129 x 97 x 30 mm
5.08” x 3.82” x 1.18”
0.285 kg (0.63 lb)
48V
110W
2.3A
90-264Vac
129 x 97 x 30 mm
5.08” x 3.82” x 1.18”
0.285 kg (0.63 lb)
Output Current
2.3A
|
Output Voltage
48V
|
Output Voltage Range
|
Output Voltage Adjustment Range
43.2-52.8Vdc
|
Output Power
110W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 0.5% (@ 115Vac & 230Vac input)
|
Load Regulation
± 0.5% (@ 115Vac & 230Vac input)
|
PARD
< 200mVpp @ 0°C to 70°C, 600mVpp typ. @ -30°C to 0°C
|
Start-up Time
500ms typ. @ 115Vac & 230Vac (100% load)
|
Hold-up Time
9ms typ. @ 115Vac, 42ms typ. @ 230Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
|
Start-up with Capacitive Loads
2,000µF Max
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30ms typ. @ 115Vac & 230Vac
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.9A typ. @ 115Vac, 1.2A typ. @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
91.5% typ. @ 230Vac
|
Max Inrush Current
55A typ. @ 230Vac (Cold Start)
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.5mA @ 240Vac/50Hz
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Aluminium / SGCC
|
|
Indicator
Green LED (DC OK)
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
Wire AWG 18-12
Current rating can refer to page 6 “Wire AWG Table” |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.285 kg (0.63 lb)
|
Dimensions
129 x 97 x
30 mm
5.08” x 3.82” x 1.18” |
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G);
10min per cycle, 60min for each axis (X, Y,Z) |
Shock Test (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.
|
Operating Temperature
-30°C to +70°C (-40°C Cold Start)
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 50°C de-rate power by 2% / °C
< 115Vac de-rate power by 0.6% / V (85% load @ 90Vac) |
Operating Humidity
20 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
|
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G);
20 min per axis for all X, Y, Z direction |
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
3
|
Bump Test (Operating)
-
|
Over Voltage Category
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
|
Overvoltage
52.8V-64.8V SELV Output, Latch Mode
|
Overload / Overcurrent
110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)
|
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with PE*4 connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs as per Telcordia SR-332
I/P: 230Vac, O/P: 100% Load, Ta: 25°C) |
Expected Cap Life Time
10 years (230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16
cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 KC: K 60950-1 EAC: TP TC 004/2011 BSMI: CNS 14336-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output:4.0 KVac
Input to Ground: 2.0 KVac Output to Ground:1.25 KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
Emission
(CE & RE)
CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
Immunity
EN/BS EN 55035, KN35, EN/BS EN 61000-6-2
Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A
|
Voltage Fluctuation and Flicker
-
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
48V
240W
5A
90-264 Vac
36V
240W
6.7A
90-264 Vac
24V
240W
10A
90-264 Vac
48V
320W
6.7A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.