Click the link below to download the file.
Get your files as below link
Dowload link
27.6V
151W
4A,1.5A
90-132Vac, 180-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.60 kg (1.32 lb)
27.6V
151W
4A,1.5A
90-132Vac, 180-264Vac (Selectable by Switch)
178 x 97 x 38 mm
7.01” x 3.82” x 1.50”
0.60 kg (1.32 lb)
Output Current
4A,1.5A
|
Output Voltage
27.6V
|
Output Voltage Range
|
Output Voltage Adjustment Range
24-28Vdc
|
Output Power
151W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
< 0.5% (90-132Vac @ 90% load,180-264Vac @ 100% load)
|
Load Regulation
< 1.0% (90-132Vac @ 0-90% load,180-264Vac @ 0-100% load)
|
PARD
< 150mVpp @ 0°C to -20°C
< 100mVpp @ > 0°C to 70°C |
Start-up Time
< 1,000ms (115Vac @ 90% load, 230Vac @ 100% load)
|
Hold-up Time
> 20ms (115Vac @ 90% load, 230Vac @ 100% load)
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5%, 0-50% & 50-100% & 10-100% load
(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1KHz) |
Start-up with Capacitive Loads
3,600μF at 27.6V/5.5A
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
Normal Mode: 0.5V typ.
Buffering Mode: 0.2V typ. |
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms (100Vac @ 90% load, 200Vac @ 100% load)
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-120Vac, 200-240Vac (Selectable by Switch)
|
Input Voltage Range
90-132Vac, 180-264Vac (Selectable by Switch)
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
< 2.5A @ 115Vac, < 1.5A @ 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
> 85.0% @ 115Vac
> 86.0% @ 230Vac |
Max Inrush Current
(Cold Start)
< 25A @ 115Vac & 230Vac |
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
< 0.5mA @ 264Vac
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
No Load: < 0.4W @ 115Vac, < 0.5W @ 230Vac
100% Load: < 23W @ 115Vac & 230Vac |
Case Chassis / Cover
AL / SGCC
|
|
Indicator
LED Indicator:
Green LED: DC OK Red LED: Battery Connected in Reverse Polarity |
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.60 kg (1.32 lb)
|
Dimensions
178 x 97 x
38 mm
7.01” x 3.82” x 1.50” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-20°C to +70°C
|
Storage Temperature
-40°C to +85°C
|
Power De-rating
I/P: 90-132Vac:
< 0°C to -20°C de-rate power by 2.25% / °C 50°C to 70°C de-rate power by 2.25% / °C I/P: 180-264Vac: < 0°C to -20°C de-rate power by 2.5% / °C 50°C to 70°C de-rate power by 2.5% / °C |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms,3 times per direction, 9 times in total
|
Vibration (Non-Operating)
IEC 60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); displacement of 0.35mm; 20 min per axis for all X, Y, Z direction
|
Storage Humidity
-
|
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
|
Pollution Degree
2
|
Bump Test (Operating)
IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000 times per direction, 3000 times in total
|
Over Voltage Category
II
|
Overvoltage
V1: <37.0V, SELV Output, Hiccup mode, Non-latching (auto-recovery)
B+: 30Vdc Max will not cause damage to the unit |
Overload / Overcurrent
Normal Mode: 105-150% of rated load current, Hiccup mode, Non-Latching (Auto recovery)
Buffering Mode: 6.05-11.0A, Latch mode |
Over Temperature
Latch mode
|
Short Circuit
Normal Mode: Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed)
Buffering Mode: Latch mode |
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class I with Primary Earth connection
|
Input Polarity Protection
-
|
Battery Polarity Protection
Yes (RED LED = ON)
|
Wrong Battery Voltage Protection
Yes, 30Vdc Max will not cause damage to the unit
|
Deep Discharge Protection
18.0V ± 0.5V
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, Ta: 25°C O/P: 13.8V/9.9A for 13V model and 27.6V/4.95A for 27V model |
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
|
Safety Certificate
-
|
Electrical Safety
SIQ Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1, UL 62368-1 and CSA C22.2 No. 62368-1 CCC: GB 9254, GB 17625.1 and GB 4943.1 CB scheme: IEC 60950-1, IEC 62368-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac Output to Ground: 0.5 KVac |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
SELV (IEC 60950-1)
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091 |
Certificates for Other Countries
-
|
BIS
IEC 60950-1, IS 13252 (Part 1)
|
KC
-
|
Emission
Generic Standards: CISPR 22, CISPR 32, EN/BS EN 55022, EN/BS EN 55032, FCC Title 47: Class B
|
Immunity
Generic Standards: EN/BS EN 55024
|
Harmonic Current Emissions
IEC/EN/BS EN 61000-3-2, Class A, GB17625.1
|
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
Nominal Battery Voltage
(Batteries not included with power supply)
24Vdc SLA Sealed lead acid battery 2 x 12Vdc SLA Sealed lead acid battery |
Battery Voltage Range
Continuously Operating: 22.0 to 27.6Vdc (nominal at 24V)
Maximum Allowed Voltage: 32Vdc Max Minimum Voltage: 16.5Vdc |
Battery Capacity
3.3AH/ 7AH/ 12AH/ 15AH
|
Battery Charging Mode
(Normal Mode)
CC-CV mode (constant current-constant voltage) at 0 to 1.5A |
End of Charge Voltage
The unit always charges battery to a fixed voltage value
|
Battery Fuse
-
|
Battery Discharging Voltage Range
-
|
Battery Charging Current
-
|
Battery Current Consumption
-
|
Discharging Current
-
|
Recommended Charging Voltage
-
|
24V
240W
10A
90-264 Vac
12V
240W
20A
90-264 Vac
36V
320W
8.9A
90-264 Vac
48V
320W
6.7A
90-264 Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.