DIN Rail Power Supply

Chrome

12V 72W / DRC-12V100W1AZ

Highlights & Features

  • Protection Class II, Double Isolation  
    (No Earth connection is required)
  • Universal AC input voltage and full power from -25°C to +55°C operation
  • Power will not de-rate for the entire input voltage range
  • Up to 86.0% efficiency
  • Low earth leakage current < 0.25mA @ 264Vac
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Overvoltage / Overcurrent / Over Temperature Protections
Dimensions (L x W x D) : 
91 x 89.9 x 55.6 mm
3.58" x 3.54" x 2.19"
Unit Weight : 
0.36 kg (0.79 lb)
Nominal Output Voltage
12V
Output Current
6A
Output Voltage Adjustment Range
12-14Vdc
Output Power
72W
Line Regulation
< 0.5% (@ 90-264Vac, 100% load)
Load Regulation
< 1% (@ 90-264Vac, 0-100% load)
PARD
< 100mVpp
Start-up Time
< 2000ms @ nominal input (100% load)
Hold-up Time
> 20ms@ 115Vac (100% load)
> 100ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 90-264Vac input, 0-100% load
(Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 1KHz)
Start-up with Capacitive Loads
3,000μF Max
Rise Time
< 70ms @ nominal input (100% load)
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac 125-375Vdc
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
DC Input Voltage Range
125-375Vdc
Input Current
< 1.50A@115Vac, < 0.90A @ 230Vac
Efficiency at 100% load
> 86.0% @ 115Vac & 230Vac
Max Inrush Current
< 30A @ 115Vac, < 65A @ 230Vac
Leakage Current
< 0.25mA @ 264Vac
Max Power Dissipation
0% load: < 0.15W@115Vac, < 0.35W @ 230Vac
100% load: < 11.5W @ 115Vac & 230Vac
Dimensions
91 x 89.9 x 55.6 mm
3.58" x 3.54" x 2.19"
Unit Weight
0.36 kg (0.79 lb)
Case Chassis / Cover
Plastic
Indicator
Green LED (DC OK)
Cooling System
Convection
Operating Temperature
-25°C to +71°C
Storage Temperature
-25°C to +85°C
Power De-rating
> 55°C de-rate power by 2.5% / °C
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms; 3 times per direction, 9 times in total
Shock (Operating)
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms; 1 time in X axis
Vibration Test (Non-Operating)
IEC 60068-2-6, Random: 5-500Hz; 2.09Grms, 20 min per axis for all X, Y, Z directions
Vibration (Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 2G peak; displacement of 0.35mm; 1 octave per min; 60 min per axis for all X, Y, Z directions
Operating Altitude
0 to 2,000 Meters (6,560 ft.)
Pollution Degree
2
Overvoltage
< 19.0V, SELV Output, Latch Mode
Overload / Overcurrent
120-150% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Latch Mode
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Degree of Protection
IP20
Protection Against Shock
Class II (No Primary Earth connection is required)
MTBF
> 500,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
Electrical Safety
TUV Bauart: EN 60950-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881)
CB Scheme: IEC 60950-1
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic Isolation
Input to Output : 3.0KVac
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991)
Safety Entry Low Voltage
SELV (EN 60950-1)
Material and Parts
RoHS Directive 2011/65/EU Compliant
Emission
CISPR 22, CISPR 32, EN 55022, EN 55032, FCC Title 47: Class B
Immunity
EN 55024
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3

Documents

Datasheet Uploaded on 14-Dec-2018 1.4 MB
.DXF Uploaded on 29-Nov-2016 88 KB
Manual Uploaded on 29-Nov-2016 1.0 MB
Mechanical Drawing Uploaded on 29-Nov-2016 34 KB
.STP Uploaded on 29-Nov-2016 1.2 MB
Image Uploaded on 29-Nov-2016 282 KB

Certificates

CB Uploaded on 29-Nov-2016 41 KB
CE Uploaded on 07-Jun-2017 119 KB
REACH Uploaded on 18-Dec-2018 545 KB
RoHS Uploaded on 18-Dec-2018 380 KB
TUV Uploaded on 29-Nov-2016 2.2 MB
UL Uploaded on 22-Apr-2019 546 KB

Related Products

Chrome 24V 60W

DRC-24V60W1AZ

Add to Comparison

Output Voltage

24V

Output Current

2.5A

Input Voltage

0-0 Vac

Dimensions

91 x 71 x 55.6 mm
3.58" x 2.80" x 2.19"

Chrome 24V 91W

DRC-24V100W1AZ

Add to Comparison

Output Voltage

24V

Output Current

3.8A

Input Voltage

0-0 Vac

Dimensions

91 x 89.9 x 55.6 mm
3.58" x 3.54" x 2.19"

Chrome 12V 25W

DRC-12V30W1AZ

Add to Comparison

Output Voltage

12V

Output Current

2.1A

Input Voltage

90-264 Vac

Dimensions

91 x 53 x 55.6 mm
3.58" x 2.09" x 2.19"

Chrome 12V 54W

DRC-12V60W1AZ

Add to Comparison

Output Voltage

12V

Output Current

4.5A

Input Voltage

0-0 Vac

Dimensions

91 x 71 x 55.6 mm
3.58" x 2.80" x 2.19"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT