DIN Rail Power Supply

CliQ II

24V 91W / DRP-24V100W1NN

Highlights & Features

  • Universal AC input range without power de-rating
  • UL 1310 safety approval
  • NEC Class 2 power supply and Limited Power Source (LPS) approvals
  • Built-in active PFC, PF > 0.99 @ 115Vac
  • Full corrosion resistant Aluminium chassis
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Conformal coating on PCBA to protect against chemical and dust pollutants
  • Overvoltage / Overcurrent / Over Temperature / Short Circuit Protections
Dimensions (L x W x D) : 
124 x 40 x 124 mm
4.88" x 1.57" x 4.88"
Unit Weight : 
0.60 kg (1.32 lb)
Nominal Output Voltage
24V
Output Current
3.8A
Output Voltage Adjustment Range
22-24 Vdc
Output Power
91W
Line Regulation
< 0.5% (@ 85-264Vac input, 100% load)
Load Regulation
< 1% at -25°C to +25°C
< 2% at +25°C to +50°C
(@ 85-264Vac input, 0-100% load)
PARD
< 150mVpp
Start-up Time
< 2,000ms @ nominal input (100% load)
Hold-up Time
> 20ms @ 115Vac,
> 30ms @ 230Vac (100% load)
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 85-264Vac input, 0-100% load
(Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz to 1kHz)
Start-up with Capacitive Loads
8,000μF Max
Nominal Input Voltage
100-240Vac
Input Voltage Range
85-264Vac 120-375Vdc
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
< 1.00A@115Vac,
< 0.53A@ 230Vac
Efficiency at 100% load
> 88.0% @ 115Vac,
> 89.0% @ 230Vac
Max Inrush Current
< 30A@ 115Vac,
< 60A @ 230Vac
Power Factor at 100% load
> 0.99 @ 115Vac,
> 0.94 @ 230Vac
Leakage Current
< 0.5mA @ 240Vac
Dimensions
124 x 40 x 124 mm
4.88" x 1.57" x 4.88"
Unit Weight
0.60 kg (1.32 lb)
Case Chassis / Cover
Aluminium
Cooling System
Convection
Operating Temperature
-25°C to +80°C
Storage Temperature
-25°C to +85°C
Power De-rating
Vertical Mounting
> 50°C de-rate power by 2.5% / °C,
> 70°C de-rate power by 4% / °C

Horizontal Mounting
> 40°C de-rate power by 2.5% / °C
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, 30G (300m/S²) for a duration of 18ms, 1 times per direction, 2 times in total
Vibration Test (Non-Operating)
IEC 60068-2-6, 10Hz to 500Hz @ 30m/S² (3G peak); 60 min per axis for all X, Y, Z direction
Over Voltage Category
II
Overvoltage
< 32V, ±10%, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent
< 100W, Constant Current, Hiccup Mode (Auto-Recovery)
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
MTBF
> 800,000 hrs. as per Telcordia SR-332
I/P: 115Vac,
O/P: 100% load, Ta: 25°C
Electrical Safety
SIQ Bauart: EN 60950-1, UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), CB scheme: IEC 60950-1, Limited Power Source (LPS)
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic Isolation
Input to Output: 4.0KVac
Input to Ground: 1.5KVac
Output to Ground: 1.5KVac
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355), CSA: CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
Electrical Equipments of Machines
EN 60204-1
Electrical Equipment for Use in Electrical Power Installations
EN 50178 / IEC 62103
Safety Entry Low Voltage
SELV (EN 60950-1)
Material and Parts
RoHS Directive 2011/65/EU Compliant
Emission
(CE & RE)
CISPR 32, EN 55032, CISPR 11, EN 55011, FCC Title 47: Class B
Immunity
Generic Standards: EN 55024, EN 61000-6-2
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
Component Power Supply for General Use
EN 61204-3

Documents

Datasheet Uploaded on 04-Jun-2019 1.2 MB
.DXF Uploaded on 13-Jul-2015 107 KB
Manual Uploaded on 11-Nov-2016 1.2 MB
Mechanical Drawing Uploaded on 13-Jul-2015 38 KB
.STP Uploaded on 13-Jul-2015 1.8 MB
Image Uploaded on 03-Nov-2016 110 KB

Certificates

CB Uploaded on 13-Jul-2015 884 KB
CE Uploaded on 27-Mar-2017 47 KB
CSA Uploaded on 13-Jul-2015 98 KB
EAC Uploaded on 27-Mar-2019 1.1 MB
REACH Uploaded on 18-Dec-2018 545 KB
RoHS Uploaded on 18-Dec-2018 380 KB
SIQ Uploaded on 13-Jul-2015 957 KB
UL Uploaded on 29-May-2019 393 KB

Related Products

CliQ 12V 100W

DRP012V100W1AA

ATEX ClassIDiv2
Add to Comparison

Output Voltage

12V

Output Current

8.33A

Input Voltage

0-0 Vac

Dimensions

121 x 50 x 118.7 mm
4.76" x 1.97" x 4.67"

CliQ II 24V 120W

DRP024V120W1BA

Add to Comparison

Output Voltage

24V

Output Current

5A

Input Voltage

85-264 Vac

Dimensions

121 x 50 x 123.1 mm
4.76" x 1.97" x 4.85"

CliQ II 24V 120W

DRP-24V120W2BN

Add to Comparison

Output Voltage

24V

Output Current

5A

Input Voltage

0-0 Vac

Dimensions

124 x 40 x 117 mm
4.88" x 1.57" x 4.61"

CliQ 24V 120W

DRP024V120W1AA

ATEX ClassIDiv2
Add to Comparison

Output Voltage

24V

Output Current

5A

Input Voltage

0-0 Vac

Dimensions

121 x 50 x 118.7 mm
4.76" x 1.97" x 4.67"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT