DIN Rail Power Supply

CliQ

24V 480W / DRP024V480W3AA

Highlights & Features

  • RoHS Compliant
  • Over load protection
  • Over voltage protection
  • Over temperature protection
  • Expected life time : 10 Years
  • Power boost 150% for 3 seconds
  • Compact design for easy handling
  • Output terminals for fast wiring and easy installation
  • With Conformal Coating (Class 1 Div 2 Hazard Loc)
  • Redundancy : DRR-20A & DRR-40A or External ORing Diode

    ** Discontinued Product **
    Replaced by : DRP024V480W3BN
Dimensions (L x W x D) : 
121 x 160 x 118.5 mm
4.76" x 6.30" x 4.67"
Unit Weight : 
1.71 kg (3.77 lb)
Tags : ATEX ClassIDiv2
Nominal Output Voltage
24V
Output Current
20A
Output Voltage Adjustment Range
22–28 Vdc
Output Power
480W
Line Regulation
< 0.5% typ. (@ 320-575Vac input, 100% load)
Load Regulation
< 1% typ. (@ 320-575Vac input, 0-100% load)
Start-up Time
< 1000ms @ nominal input, 100% load (25°C)
Hold-up Time
> 25ms @ 3 x 400Vac,
> 50ms @ 3 x 500Vac (100% load, 25°C)
Dynamic Response (Overshoot & Undershoot O/P Voltage)
±5% @ 0-100% load
Start-up with Capacitive Loads
10,000µF @ nominal input & nominal O/P voltage 24V (25°C)
Nominal Input Voltage
400-500Vac
Input Voltage Range
320-575Vac 450-800 Vdc
Nominal Input Frequency
50 - 60Hz
Input Frequency Range
47-63Hz
Nominal DC Input Voltage
565-700Vdc
Input Current
< 1.60A @ 400Vac,
< 1.10A @ 500Vac
Efficiency at 100% load
> 87.0% @ 3 x 400Vac & 3 x 500Vac
Max Inrush Current
< 50A @3 x 400Vac & 3 x 500Vac
Power Factor at 100% load
Conform to EN61000-3-2
Leakage Current
< 3.5mA @ 500Vac
Dimensions
121 x 160 x 118.5 mm
4.76" x 6.30" x 4.67"
Unit Weight
1.71 kg (3.77 lb)
Case Chassis / Cover
Aluminium
Cooling System
Convection
Operating Temperature
-20°C to +50°C, with operation to 70°C possible with a linear derating to half power from 50°C to 70°C.
Storage Temperature
-25°C to +85°C
Power De-rating
> 50°C de-rate power by 2.5% /°C
Operating Humidity
< 95% RH
Shock Test (Non-Operating)
IEC60068-2-27, 30G (300m/s2)
Vibration Test (Non-Operating)
IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 90 min per axis for all X, Y, Z direction
Overvoltage
32V +10%/-10%, SELV output, Hicc-up Mode, Non-Latching (Auto recovery).
Overload / Overcurrent
> 150% of rated load current, Hicc-up Mode, Non-Latching (Auto recovery).
Over Temperature
< 80°C Ambient Temp@ 100% load. Non-Latching (Auto-recovery).
Short Circuit
Hicc-up Mode, Non-Latching, (Auto-recovery when the fault is removed).
Degree of Protection
IPX0
Protection Against Shock
Class I with Primary Earth connection
MTBF
> 300,000 hrs, as per BELL CORE STD or IEC61709
Electrical Safety
SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CSA to UL 60950-1 and CSA C22.2 No. 60950-1 (File No. 181564)
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
In conformance with Equipment for explosive atmospheres (ATEX) directive 2014/34/EU
Galvanic Isolation
Input to Output: 4.0KVac
Input to Ground: 2.0KVac
Output to Ground: 1.5KVac
Industrial Control Equipment
UL listed to UL 508, CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
Hazardous Location / ATEX
cCSAus to CSA C22.2 No. 213-M1987, ANSI / ISA 12.12.01:2007 [Class I, Division 2, Group A, B, C, D T4, Ta = -20°C to +80°C (> +50°C derating)]
EN 60079-0:2009, EN 60079-15:2010 [II 3G Ex nA IIC T4 Gc, Ta = -20°C to +80°C (> +50°C derating))
II 3 G ATEX 2014/34/EU
Certificate No. EPS 09 ATEX 1 215 X;
For IEC 60079-0, IEC 60079-15
Electrical Equipment for Use in Electrical Power Installations
EN 50178 / IEC 62103
Material and Parts
RoHS Directive 2011/65/EU Compliant
Emission
CISPR 32, EN 55032, CISPR 11, EN 55011, FCC Title 47: Class B
Immunity
EN 55024, EN 61000-6-2
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3

Documents

Datasheet Uploaded on 27-Dec-2017 1.2 MB
.DXF Uploaded on 13-Jul-2015 111 KB
Manual Uploaded on 13-Jul-2015 1.9 MB
Mechanical Drawing Uploaded on 13-Jul-2015 32 KB
.STP Uploaded on 21-Jul-2015 1.4 MB
Image Uploaded on 03-Nov-2016 124 KB

Certificates

ATEX Uploaded on 21-Jul-2015 1.0 MB
CB Uploaded on 13-Jul-2015 1.2 MB
CE Uploaded on 13-Jul-2015 352 KB
CSA Uploaded on 13-Jul-2015 1.1 MB
EAC Uploaded on 27-Mar-2019 1.1 MB
Hazloc Uploaded on 13-Jul-2015 128 KB
REACH Uploaded on 18-Dec-2018 545 KB
RoHS Uploaded on 18-Dec-2018 380 KB
SIQ Uploaded on 13-Jul-2015 594 KB
UL Uploaded on 13-Jul-2015 68 KB

Related Products

CliQ II 24V 480W

DRP024V480W3BA

Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

0-0 Vac

Dimensions

121 x 140 x 117.3 mm
4.76" x 5.51" x 4.62"

CliQ 24V 480W

DRP024V480W1AA

ATEX ClassIDiv2
Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

0-0 Vac

Dimensions

121 x 160 x 118.5 mm
4.76" x 6.30" x 4.67"

CliQ II 24V 480W

DRP024V480W1BA

Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

85-264 Vac

Dimensions

121 x 144 x 118.6 mm
4.76" x 5.67" x 4.67"

CliQ II 48V 480W

DRP048V480W1BA

Add to Comparison

Output Voltage

48V

Output Current

10A

Input Voltage

0-0 Vac

Dimensions

121 x 144 x 118.6 mm
4.76" x 5.67" x 4.67"