LED Driver

EUCI BA

15W / EUCI-015035BA

Highlights & Features

  • Constant current design
  • EMEA AC input voltage from 220-240Vac
  • Up to 86.5% efficiency
  • Optional strain-relief set for independent applications
  • Build-in active PFC and confirm to harmonic current IEC/EN 61000-3-2, Class C
  • Bluetooth low energy Mesh dimming available
  • 1% -100% dimming range
  • Two channels for color mix application
Dimensions (L x W x D) : 
100 x 43 x 25 mm
3.94" x 1.69" x 0.98"
Unit Weight : 
0.08 kg (0.18 lb)
Output Current
0.35A
Output Power
15W
Output Current Adjustment Range
0.2A
Line Regulation
± 1% (@ 220-240Vac input)
Load Regulation
± 5% (@ Min-Max output voltage)
Start-up Time
750ms max. @ 230Vac
Output Voltage Range
15-42Vdc
Nominal Input Voltage
220-240Vac
Nominal Input Frequency
50-60Hz (47-63Hz)
Efficiency at 100% load
230Vac: 86.5% typ.
Power Factor at 100% load
Full Load: > 0.95 ; 50% load: > 0.9 @ 230Vac
Leakage Current
< 0.7mA @ 240Vac
Total Harmonic Distortion
THD < 20% with load ≥ 50% @ 230Vac
Dimensions
100 x 43 x 25 mm
3.94" x 1.69" x 0.98"
Unit Weight
0.08 kg (0.18 lb)
Wire
Terminal, 2-pole (Line / Neutral)
Conductor 0.75~1.5 mm²
Strip length 8.5…9.5mm

Terminal, 4-pole
(Positive / Negative / Positive / Negative)
Conductor 0.75~1.5 mm²
Strip length 8.5…9.5mm
Noise Sound Pressure Level (SPL)
24dBA (30cm distance)
Operating Temperature
,-25°C to +50°C
Storage Temperature
-25°C to +85°C
Operating Humidity
10 to 90% RH (Non-Condensing)
Overvoltage
Max. 50V, Auto-Recovery when the fault is removed
Overload / Overcurrent
Max. 50V, Auto-Recovery when the fault is removed
Over Temperature
Auto-Recovery when the fault is removed
Short Circuit
Auto-Recovery when the fault is removed
MTBF
500,000 hrs. @ta: +50°C (as per Telcordia SR-332 , total failure rate less than 10% )
Expected Cap Life Time
50,000 hrs. @ lifetime case temperature
Electrical Safety
CB scheme to IEC 61347-1, IEC 61347-2-13
ENEC to EN 61347-1, EN 61347-2-13, EN 62384
CCC, GB19510.1, GB19510.14
SELV
CE
In conformance with EMC Directive and Low Voltage Directive
Galvanic Isolation
See datasheet
Emission
Compliance to EN 55015 Class B
Immunity
Compliance to EN 61547
Harmonic Current Emissions
IEC 61000-3-2
Voltage Fluctuation and Flicker
IEC 61000-3-3