LED Driver

USCO-PRO

V 150W / USCO-150140GC

Highlights & Features

  • Constant current design
  • Universal AC input voltage from 99-305Vac
  • High efficiency up to 95%
  • Wide operating temperature range -40oC ~ +60oC
  • With IP67 protection for most outdoor applications
  • Built-in Active PFC and conforms to harmonic current IEC/EN 61000-3-2, Class C
  • Adjustable constant current level through program tool
  • Common mode 6kV and differential mode 6kV surge immunity
  • Suitable for Dry / Damp / Wet location
  • 5 years warranty
Dimensions (L x W x D) : 
220 x 63 x 37 mm
8.66" x 2.48" x 1.46"
Unit Weight : 
1.1 kg (2.43 lb)
Output Power
150W
Line Regulation
± 1% (@ 110-277Vac input)
Load Regulation
± 3% (@ Min-Max output voltage)
Start-up Time
500ms max. @ 110-277Vac (full load)
Hold-up Time
16ms typ. @ 110-277Vac (full load)
Output Voltage Range
72-214Vdc
Nominal Input Voltage
110-277Vac (99-305Vac)
Nominal Input Frequency
50-60Hz (47-64Hz)
Efficiency at 100% load
120Vac: 91.5%@0.7A typ.
230Vac: 93.0%@0.7A typ.
277Vac: 93.0%@0.7A typ.
Power Factor at 100% load
>0.98@110/120Vac, >0.95@230Vac, >0.92@277Vac;
Leakage Current
<0.7mA peak @ 277Vac
Total Harmonic Distortion
THD<20% with load≧50% at 110/120/230Vac input and load≧75% at 277Vac input
Dimensions
220 x 63 x 37 mm
8.66" x 2.48" x 1.46"
Unit Weight
1.1 kg (2.43 lb)
Noise Sound Pressure Level (SPL)
< 24dbA (30cm distance)
Wire
Input: Line: Brown, Neutral: Blue, PE: Yellow/Green, Cable Length 300mm
Output: Positive: Brown, Negative: Blue; NTC/PRG: Black; Cable Length 300mm
Dimming: Dim(+): Violet, Dim(-): Gray, +12V: Black/White, Cable Length 300mm
Operating Temperature
-40°C to +60°C (+60°C ~ +70°C Load de-rating)
Storage Temperature
-40°C to +85°C
Power De-rating
>60°C(75/100/150/200W), >55°C(250W), >50°C(320W) de-rating power & <110Vac de-rating power “OUTPUT LOAD VS INPUT VOLTAGE” & “OUTPUT LOAD VS AMBIENT TEMPERATURE”
Operating Humidity
10 to 90% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration Test (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Overvoltage
215-250Vdc, Auto-Recovery when the fault is removed
Overload / Overcurrent
Reduce output current. Auto-Recovery when the fault is removed
Over Temperature
Reduce output current. Auto-Recovery when the fault is removed
Short Circuit
Auto-Recovery when the fault is removed
MTBF
500 khours at ta=+50°C (75-250W), ta=+45°C (320W), Telcordia SR-332.
Safety Certificate
CB scheme to IEC 61347-1, IEC 61347-2-13 (independent)
ENEC to EN 61347-1, EN 61347-2-13
UL/cUL (cRUus) to UL 8750, type”HL” & type”TL”
Compliance to IEC/EN/UL 60950-1
SELV for 75W
CE
In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
Galvanic Isolation
See datasheet
Emission
Compliance to EN 55015:2013 Class B; 47 CFR FCC Part 15, Subpart B, Class B
Immunity
Compliance to EN 61547:2009
Harmonic Current Emissions
IEC 61000-3-2:2014
Voltage Fluctuation and Flicker
IEC 61000-3-3:2013

Documents

NEW Datasheet Uploaded on 01-Feb-2019 2.5 MB
NEW i programming GUI (QT) V2.0.0 Uploaded on 14-Feb-2019 17.6 MB
NEW Mechanical Drawing Uploaded on 01-Feb-2019 620 KB
NEW .STP Uploaded on 01-Feb-2019 1.6 MB
NEW Image Uploaded on 01-Feb-2019 49 KB

Certificates

NEW CB Uploaded on 11-Mar-2019 132 KB
NEW CE Uploaded on 11-Mar-2019 74 KB
NEW ENEC Uploaded on 11-Mar-2019 885 KB
NEW REACH Uploaded on 11-Mar-2019 501 KB
NEW RoHS Uploaded on 11-Mar-2019 89 KB
NEW UL Uploaded on 11-Mar-2019 106 KB
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT