Medical Power Solution

Medical Enclosed

24V 200W / MDS-200ADB24 AA

Highlights & Features

  • Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
  • Compliant with IEC 60601-1-2 4th Ed. Requirements
  • 2.5" x 4.5" x 1.8" Package
  • Power Good Signal
  • up to 800K Hours MTBF
  • up to 120W convection, 200W forced air
Dimensions (L x W x D) : 
113.9 x 64.7 x 44.7 mm
4.48" x 2.55" x 1.76"
Unit Weight : 
0.345kg (0.76 lb)
Nominal Output Voltage
24V
Output Current
8.33A
Output Power
200W
Line Regulation
±0.5%
Load Regulation
±1%
Start-up Time
2000ms @ 115Vac
Hold-up Time
12ms@115Vac, tested with 120W load
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50-100% load
Rise Time
100ms
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
2.5A
Efficiency at 100% load
92% @ 115Vac/60Hz
93% @ 230Vac/50Hz, Reference
Max Inrush Current
60A@230Vac, cold start
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
Dimensions
113.9 x 64.7 x 44.7 mm
4.48" x 2.55" x 1.76"
Unit Weight
0.345kg (0.76 lb)
Case Chassis / Cover
Enclosed cover(SPCC)
Indicator
NA
Cooling System
NA
Operating Temperature
Absolute Max
-10°C to+70°C, supported powerlinearly de-rate from 50°C to 50% ratedup to 70°C
Note: see power de-rating curve
Storage Temperature
-40°C to +85°C
Power De-rating
Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade)
Operating Humidity
5-95% RH (Non-Condensing)
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
Operating Altitude
5,000 meters (16402 feet)
Overvoltage
125% of rated voltage, Latch Mode
Overload / Overcurrent
Main output 160% of rated current
Hiccup Mode(Non-Latching, Auto-Recovery)
Over Temperature
Latch Mode
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
MTBF
800 Khrs based on Telecordia SR-332
Expected Cap Life Time
Operating life at 115Vac, 110W, ambient 25 °C, Convection Air Flow: 26,280Hrs
CE
MDD Directive 93/42/EEC
Medical Safety
IEC60601-12nd, 3rdand 3rd+A1 edition CB report TUV EN60601-1:2006 UL60601-1+CAN/CSA 60601-1: (Ed.3.2005)
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500Vac(PSU can support PoE applications with Primary to FG 2500Vac test.)
Output to/Ground(1XMOPP): 1500Vac ( Type BF application rated)
Emission
Class I model: EN55011, EN55022, FCC Title 47: Class B
Harmonic Current Emissions
IEC61000-3-2 Meet Class D limit
Voltage Fluctuation and Flicker
IEC61000-3-3

Documents

Datasheet Uploaded on 04-Dec-2018 1.0 MB
.DXF Uploaded on 07-Jun-2017 840 KB
Mechanical Drawing Uploaded on 09-Jun-2016 192 KB
.STP Uploaded on 08-Jun-2016 1.3 MB
Image Uploaded on 03-Nov-2016 924 KB

Certificates

CB Uploaded on 05-Mar-2019 411 KB
CCC Uploaded on 24-Apr-2018 8.3 MB
CE Uploaded on 15-Aug-2016 116 KB
UPDATED REACH Uploaded on 20-Mar-2019 107 KB
RoHS Uploaded on 18-Dec-2018 275 KB

Related Products

Medical Enclosed 12V 300W

MDS-300ADB12 AA

-
Add to Comparison

Output Voltage

12V

Output Current

25A

Input Voltage

90-264 Vac

Dimensions

140 x 88.9 x 45 mm
5.5" x 3.5" x 1.75"

Medical Enclosed 18V 300W

MDS-300ADB18 AA

-
Add to Comparison

Output Voltage

18V

Output Current

16.66A

Input Voltage

90-264 Vac

Dimensions

140 x 88.9 x 45 mm
5.5" x 3.5" x 1.75"

Medical Enclosed 24V 300W

MDS-300ADB24 AA

-
Add to Comparison

Output Voltage

24V

Output Current

12.5A

Input Voltage

90-264 Vac

Dimensions

140 x 88.9 x 45 mm
5.5" x 3.5" x 1.75"

Medical Enclosed 12V 200W

MDS-200ADB12 AA

-
Add to Comparison

Output Voltage

12V

Output Current

25A

Input Voltage

90-264 Vac

Dimensions

113.9 x 64.7 x 44.7 mm
4.48" x 2.55" x 1.76"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT