Medical Power Solution

Medical Enclosed

12V 400W / MDS-400ADB12 AA

Highlights & Features

  • Safety Approvals to IEC 60601-1 3.1rd ed. & IEC 60950-1
  • Compliant with IEC 60601-1-2 4th Ed. Requirements
  • Up to 400W forced air
  • IT & Medical Safety Approvals
Dimensions (L x W x D) : 
140.0 x 88.9 x 44.4 mm
5.51" x 3.50" x 1.75"
Unit Weight : 
0.605kg (1.33 lb)
Nominal Output Voltage
12V
Output Current
33.33A
Output Power
400W
Line Regulation
±0.5%
Load Regulation
±1%
Start-up Time
2000ms @ 115Vac
Hold-up Time
10ms@115Vac, with 400W load
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50-100% load
Rise Time
100ms
Nominal Input Voltage
100-240Vac
Input Voltage Range
90-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
5.5A
Efficiency at 100% load
89.5% @ 115Vac/60Hz
91.5% @ 230Vac/50Hz
Max Inrush Current
40A@230Vac, cold start
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
Dimensions
140.0 x 88.9 x 44.4 mm
5.51" x 3.50" x 1.75"
Unit Weight
0.605kg (1.33 lb)
Case Chassis / Cover
Enclosed cover(SPCC)
Indicator
NA
Cooling System
TBD
Operating Temperature
Absolute Maximum/Minimum Rating.
-10°C to +70°C. Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade) for forced air.
Storage Temperature
-40°C to +85°C
Power De-rating
Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade)
Operating Humidity
5-95% RH (Non-Condensing)
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
Operating Altitude
5,000 meters (16402 feet)
Overvoltage
135% of rated voltage, Latch Mode
Overload / Overcurrent
Main output 160% of rated current
Standby 3A max
Hiccup Mode(Non-Latching, Auto-Recovery)
Over Temperature
Latch Mode
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
MTBF
500 kHrs based on Telecordia SR-332
Expected Cap Life Time
16CFM Air Flow 500 kHrs based on Telecordia SR-332 Operating life at 115Vac, 400W, ambient 25 °C, 16CFM Air Flow: 26,280Hrs
CE
MDD Directive 93/42/EEC
Medical Safety
IEC60601-12nd and 3rd, and 3rd+A1 edition CB report TUV EN60601-1:2006 UL60601-1+CAN/CSA 60601-1: (Ed.3.2005)
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500Vac(PSU can support PoE applications with Primary to FG 2500Vac test.)
Output to/Ground(1XMOPP): 1500Vac ( Type BF application rated)
Emission
EN55011 & compliant with EN55032, FCC Title 47:Class B
Harmonic Current Emissions
IEC61000-3-2 Meet Class D limit
Voltage Fluctuation and Flicker
IEC61000-3-3

Documents

Datasheet Uploaded on 30-Jan-2019 1.1 MB
.DXF Uploaded on 07-Jun-2017 1.0 MB
Mechanical Drawing Uploaded on 09-Jun-2016 143 KB
.STP Uploaded on 08-Jun-2016 3.0 MB
Image Uploaded on 03-Nov-2016 902 KB

Certificates

CB Uploaded on 13-Jul-2016 798 KB
CCC Uploaded on 13-Jul-2016 8.9 MB
CE Uploaded on 16-Aug-2016 124 KB
REACH Uploaded on 20-Mar-2019 107 KB
RoHS Uploaded on 18-Dec-2018 275 KB
TUV Uploaded on 13-Jul-2016 6.0 MB
UL Uploaded on 13-Jul-2016 1.7 MB

Related Products

Medical Enclosed 12V 300W

MDS-300ADB12 AA

-
Add to Comparison

Output Voltage

12V

Output Current

25A

Input Voltage

0-0 Vac

Dimensions

140 x 88.9 x 45 mm
5.5" x 3.5" x 1.75"

Medical Enclosed 18V 300W

MDS-300ADB18 AA

-
Add to Comparison

Output Voltage

18V

Output Current

16.66A

Input Voltage

0-0 Vac

Dimensions

140 x 88.9 x 45 mm
5.5" x 3.5" x 1.75"

Medical Enclosed 12V 200W

MDS-200ADB12 AA

-
Add to Comparison

Output Voltage

12V

Output Current

25A

Input Voltage

90-264 Vac

Dimensions

113.9 x 64.7 x 44.7 mm
4.48" x 2.55" x 1.76"

Medical Enclosed 24V 200W

MDS-200ADB24 AA

-
Add to Comparison

Output Voltage

24V

Output Current

8.33A

Input Voltage

90-264 Vac

Dimensions

113.9 x 64.7 x 44.7 mm
4.48" x 2.55" x 1.76"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT