Panel Mount Power Supply

PMT

5V 50W / PMT-5V50W1AA

Highlights & Features

  • Universal AC input range
  • Power will not de-rate from input voltage 100Vac to 264Vac
  • High MTBF > 700,000 hrs. per Telcordia SR-332
  • Short Circuit / Overvoltage / Overload / Over Temperature Protections
  • Versatile connector options (Terminal Block, Front Face)


Dimensions (L x W x D) : 
98 x 98 x 38 mm
3.86" x 3.86" x 1.50"
Unit Weight : 
0.23 kg (0.51 lb)
Nominal Output Voltage
5V
Output Current
10A
Output Voltage Adjustment Range
4.50-5.50Vdc
Output Power
50W
Line Regulation
< 0.5% typ. (@ 115Vac & 230Vac input, 100% input)
Load Regulation
< 1% typ. (@ 115Vac & 230Vac input, 0-100% input)
PARD
< 80mVpp @ 25°C to 50°C,
< 160mVpp @ -10°C to 0°C
Start-up Time
1,200ms typ.@ 115Vac,
500ms typ. @ 230Vac (100% load)
Hold-up Time
20ms typ. @ 115Vac, 100ms typ. @ 230Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 10% (1000mVp-p) @ 0-100% load
Start-up with Capacitive Loads
8,000μF Max
Nominal Input Voltage
100-240Vac
Input Voltage Range
85-264Vac
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
Input Current
< 1.10A@115Vac, < 0.65A @ 230Vac
Efficiency at 100% load
82.0% typ. @ 230Vac
Max Inrush Current
45A typ. @ 230Vac
Leakage Current
< 1mA @ 240Vac
Dimensions
98 x 98 x 38 mm
3.86" x 3.86" x 1.50"
Unit Weight
0.23 kg (0.51 lb)
Case Chassis / Cover
Aluminium / SGCC
Indicator
Green LED (DC OK)
Cooling System
Convection
Operating Temperature
-10°C to +70°C
Storage Temperature
-25°C to +85°C
Power De-rating
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 1.33% / V
(80% load @ 85Vac)
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration Test (Non-Operating)
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
Operating Altitude
0 to 5,000 Meters (0 to 16,400 ft)
Pollution Degree
2
Overvoltage
5.75-7.50V, SELV Output, Hiccup Mode,
Non-Latching (Auto-Recovery)
Overload / Overcurrent
105-150% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
Over Temperature
Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Protection Against Shock
Class I with PE connection
MTBF
> 700,000 hrs. as per Telcordia SR-332
Electrical Safety
TUV Bauart to EN60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943
Galvanic Isolation
Input to Output: 3.0KVac
Input to Ground: 1.5KVac
Output to Ground: 0.5KVac
Safety Entry Low Voltage
SELV (EN 60950-1)
Material and Parts
RoHS Directive 2011/65/EU Compliant
Emission
CISPR 32, EN 55032, FCC Title 47: Class B
Immunity
EN 55024
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3

Documents

Datasheet Uploaded on 26-Dec-2018 1.1 MB
.DXF Uploaded on 13-Jul-2015 750 KB
Manual Uploaded on 13-Jul-2015 1.1 MB
Mechanical Drawing Uploaded on 30-Mar-2018 296 KB
.STP Uploaded on 13-Jul-2015 2.9 MB
Image Uploaded on 03-Nov-2016 96 KB

Certificates

CB Uploaded on 23-Aug-2016 696 KB
CCC Uploaded on 23-Aug-2016 694 KB
CE Uploaded on 30-Mar-2017 115 KB
REACH Uploaded on 18-Dec-2018 545 KB
RoHS Uploaded on 18-Dec-2018 380 KB
TUV Uploaded on 13-Jul-2015 1.4 MB
UL Uploaded on 01-Apr-2019 448 KB

Related Products

PMT 12V 50W

PMT-12V50W1AA

Add to Comparison

Output Voltage

12V

Output Current

4.17A

Input Voltage

0-0 Vac

Dimensions

98 x 98 x 38 mm
3.86" x 3.86" x 1.50"

PMT 15V 51W

PMT-15V50W1AA

Add to Comparison

Output Voltage

15V

Output Current

3.4A

Input Voltage

0-0 Vac

Dimensions

98 x 98 x 38 mm
3.86" x 3.86" x 1.50"

PMT 24V 50W

PMT-24V50W1AA

Add to Comparison

Output Voltage

24V

Output Current

2.1A

Input Voltage

0-0 Vac

Dimensions

98 x 98 x 38 mm
3.86" x 3.86" x 1.50"

PMT 12V 99W

PMT-D1V100W1AA

Add to Comparison

Output Voltage

12V

Output Current

7A

Input Voltage

0-0 Vac

Dimensions

178 x 97 x 38 mm
7.01" x 3.82" x 1.50"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT