12V
60W
5A
85-264Vac
108 x 46 x 29.5 mm
4.25” x 1.81” x 1.16”
0.18 kg (0.40 lb)
12V
60W
5A
85-264Vac
108 x 46 x 29.5 mm
4.25” x 1.81” x 1.16”
0.18 kg (0.40 lb)
Output Current
5A
|
Output Voltage
12V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
60W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1%
|
Load Regulation
± 5.0%
|
PARD
0°C to 40°C: < 240mVpp
-10°C to 0°C: < 480mVpp |
Start-up Time
1000ms (typ.) at 115Vac, 500ms (typ.) at 230Vac
|
Hold-up Time
12ms (typ.) at 115Vac, 60ms (typ.) at 230Vac
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
30mS (typ.) at 115Vac & 230Vac
|
Input Voltage
100-240Vac
|
Input Voltage Range
85-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
1.4A max. at 115Vac, 1.0A max. at 230Vac
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
87.6% typ. at 115Vac, 90.2% typ. at 230Vac
|
Max Inrush Current
-
|
Charging Time
-
|
Power Factor at 100% load
-
|
Leakage Current
0.1mA @ 240Vac/50Hz (max.)
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Max Power Dissipation
-
|
Case Chassis / Cover
PC
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Unit Weight
0.18 kg (0.40 lb)
|
Dimensions
108 x 46 x
29.5 mm
4.25” x 1.81” x 1.16” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-10°C to +60°C
(-20°C cold start @ 100% Load) |
Storage Temperature
-40°C to +85°C
|
Power De-rating
> 40°C de-rating power by 2.5% / °C
< 90Vac de-rating power by 2% / V |
Operating Humidity
5 to 95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
Half sine wave, 50G, 11ms, 1 shocks for each direction, 6 direction
|
Vibration (Non-Operating)
5-500Hz, 2.09Grms, 20 minute for X,Y,Z axis
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
Operating Altitude
Up to 5,000 meters (up to 16,400 feet)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Overvoltage
13.2-18.0V, Latch Mode
|
Overload / Overcurrent
5.25-10.00A Auto-Recovery when the fault is removed
|
Over Temperature
Latch Mode
|
Short Circuit
Auto-Recovery when the fault is removed
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
Class II
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
MTBF
> 700,000 hrs. per Telcordia SR-332 at Input: 115Vac, Output: 100% load, Ta: 25°C
|
Expected Cap Life Time
5 years (50% load @ 25°C)
|
Safety Certificate
-
|
Electrical Safety
IEC/UL/EN 60950-1; IEC/UL/EN 62368-1
BSMI CNS14336-1 CCC GB4943.1-2011 PSE J60950-1(H29) KC K60950-1 |
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
|
Medical Safety
-
|
Galvanic Isolation
Input to Output: 3000Vac
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
RoHS Directive 2011/65/EU Compliant
|
Isolation Resistance
-
|
PE Resistance
-
|
Emission
CISPR/EN 55032 Class B
BSMI CNS13438 FCC Part 15, ICES-003, ANSI C63.4 GB/T9254- 2008 KN32 |
Immunity
EN55024; KN35
|
Harmonic Current Emissions
IEC 61000-3-2: Class D; GB17625.1-2003
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
IEC 61000-4-11
|
Component Power Supply for General Use
-
|
24V
120W
5A
90-264Vac
24V
150W
6.25A
90-264Vac
24V
150W
6.25A
90-264Vac
24V
90W
3.75A
90-264Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.