DIN Rail Power Supply

CliQ III

24V 480W / DRP-24V480W1CAN

Highlights & Features

  • Universal AC input voltage range
  • Built-in constant current circuit for charging application
  • High efficiency of up to 94% at 230Vac
  • Power Boost of 150% for 5 seconds
  • Advanced Power Boost (APB) of 200% for 50ms
  • SEMI F47 compliance at 120Vac
  • Extreme low temperature cold start at -40°C
  • Built-in DC OK Contact and LED indicator for DC OK
  • Conformal coating on PCBA to protect against common dust and chemical pollutants


Dimensions (L x W x D) : 
124 x 82 x 127 mm
4.88" x 3.23" x 5.00"
Unit Weight : 
1.20 kg (2.65 lb)
Nominal Output Voltage
24V
Output Current
20A
Output Voltage Adjustment Range
24-28Vdc
Output Power
480W
Line Regulation
0.5% (@ 88-264Vac input, 100% load)
Load Regulation
1% (@ 88-264Vac input, 0-100% load)
PARD
100mVpp Max.
Start-up Time
400ms Max. @ 24V, 20A
Hold-up Time
21ms Typ. @ 24V, 20A
15ms Min. @ 24V, 20A
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ 0-100% load
Start-up with Capacitive Loads
10,000µF Max.
Rise Time
150ms Max. @ 24V, 20A
Nominal Input Voltage
100-240Vac
Input Voltage Range
100-264Vac (Continuously operating)
88-100Vac (With power de-rating)
Nominal Input Frequency
50-60Hz
Input Frequency Range
47-63Hz
DC Input Voltage Range
100-375Vdc (Continuously operating, with safety approval according to IEC/EN/UL 60950-1)
88-100Vdc (With power de-rating)
Input Current
4.52A Typ. @ 115 Vac, 2.31A typ. @ 230Vac
Efficiency at 100% load
92.55% Typ. @ 115Vac, 94.00% Typ. @ 230Vac
Max Inrush Current
(Cold Start)
12.8A Typ. @ 115Vac, 30.6A Typ. @ 230Vac, 40A Max. @ 115Vac, 80A Max. @ 230Vac
Power Factor at 100% load
0.99 Typ. @ 115Vac, 0.96 Typ. @ 230Vac, 0.99 Min. @ 115Vac, 0.95 Min. @ 230Vac
Leakage Current
(Enclosure to Neutral)
< 0.49mA / 1.12mA: 110Vac, 50Hz, TN/TT system / IT system
< 0.58mA / 1.29mA: 132Vac, 50Hz, TN/TT system / IT system
< 1.12mA / 2.55mA: 264Vac, 50Hz, TN/TT system / IT system
Max Power Dissipation
At 24V, 0A: 4.19W Typ. @ 115Vac, 4.40W Typ. @ 230Vac, 10.0W Max. @ 115Vac, 11.0W Max. @ 230Vac
At 24V, 20A: 38.73W Typ. @ 115Vac, 30.85W Typ. @ 230Vac, 47.73W Max. @ 115Vac, 36.13W Max. @ 230Vac
Dimensions
124 x 82 x 127 mm
4.88" x 3.23" x 5.00"
Unit Weight
1.20 kg (2.65 lb)
Case Chassis / Cover
Aluminium
Indicator
Green LED (DC OK)
Cooling System
Convection
Operating Temperature
-25°C to +70°C (Cold start -40°C)
Storage Temperature
-40°C to +85°C
Power De-rating
Vertical Mounting:
AC input > 60°C de-rate by 2.5% / °C
DC input > 50°C de-rate by 2.5% / °C
Horizontal Mounting: > 40°C de-rate by 2.5% / °C
Input Voltage:
AC input < 100Vac de-rate by 0.83% / V
DC input < 100Vdc de-rate by 1.67% / V
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine Wave: 30G for a duration of 18ms; 3 times per direction, 9 times in total
Vibration Test (Non-Operating)
IEC 60068-2-6, Sine Wave: 10-500Hz; 3G peak; displacement of 0.35mm; 60 min per axis for all X, Y, Z directions
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
Pollution Degree
2
Bump Test (Operating)
IEC 60068-2-29, Half Sine Wave: 10G for a duration of 11ms, 1,000 times per direction, 6,000 times in total
Over Voltage Category
III (operating altitude 2,500 Meters)
II (operating altitude 5,000 Meters)
According to IEC/EN 62477-1 / EN 60204-1 (clearance and creepage distances) and IEC 62103 (safety part)
Overvoltage
28.8 - 35.2V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent
125 – 170% of rated load current, Constant current, Hiccup Mode (Auto-Recovery)
Over Temperature
< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed): Load impedance ≤ 100mOhm
Degree of Protection
IP20
Protection Against Shock
Class I with Primary Earth connection
MTBF
1,041,600 hrs.: I/P: 115Vac, O/P: 24V, 20A, Ta: 25°C
621,000 hrs.: I/P: 115Vac, O/P: 24V, 20A, Ta: 40°C
Expected Cap Life Time
O/P: 24V, 20A, Ta: 25°C: 131,400hrs. @ 115Vac & 230Vac
O/P: 24V, 10A, Ta: 40°C: 131,400hrs. @ 115Vac & 230Vac
O/P: 24V, 20A, Ta: 60°C: 15,400hrs. @ 115Vac, 20,300hrs. @ 230Vac
O/P: 24V, 3.75A, Ta: 60°C: 30,500hrs.@ 115Vac, 38,500hrs. @ 230Vac
Electrical Safety
SIQ Bauart: EN 60950-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)
CB scheme: IEC 60950-1
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Galvanic Isolation
Input to Output: 4.0KVac
Input to Ground: 2.0KVac
Input to DC OK relay contact: 4.0KVac
Output to Ground: 1.5KVac
Output to DC OK relay contact: 0.5KVac
DC OK relay contact to PE: 1.5KVac
Industrial Control Equipment
UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)
Electrical Equipments of Machines
EN 60204-1 (over voltage category III)
Electrical Equipment for Use in Electrical Power Installations
IEC/EN 62477-1 / IEC 62103
Safety Entry Low Voltage
PELV (EN 60204-1), SELV (EN 60950-1)
Material and Parts
RoHS Directive 2011/65/EU Compliant (EN 50581)
PE Resistance
< 0.1Ohm
Emission
(CE & RE)
Generic Standards: EN 61000-6-3
CISPR 32, EN 55032, CISPR 11, EN 55011, FCC Title 47: Class B
Immunity
Generic Standards: EN 55024, EN 61000-6-2
Harmonic Current Emissions
IEC/EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
Component Power Supply for General Use
EN 61204-3

Documents

Datasheet Uploaded on 14-Dec-2018 1.1 MB
.DXF Uploaded on 08-Aug-2018 194 KB
Mechanical Drawing Uploaded on 31-Jul-2018 150 KB
.STP Uploaded on 08-Aug-2018 2.7 MB
Manual Uploaded on 01-Aug-2018 1.0 MB
Image Uploaded on 31-Jul-2018 467 KB

Certificates

CB Uploaded on 31-Jul-2018 698 KB
CE Uploaded on 31-Jul-2018 210 KB
EAC Uploaded on 28-Jul-2016 1.2 MB
REACH Uploaded on 18-Dec-2018 545 KB
RoHS Uploaded on 18-Dec-2018 380 KB
SIQ Uploaded on 31-Jul-2018 716 KB
UL Uploaded on 20-Dec-2017 68 KB

Related Products

CliQ II 24V 480W

DRP024V480W1BA

Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

85-264 Vac

Dimensions

121 x 144 x 118.6 mm
4.76" x 5.67" x 4.67"

CliQ 24V 480W

DRP024V480W1AA

ATEX ClassIDiv2
Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

85-264 Vac

Dimensions

121 x 160 x 118.5 mm
4.76" x 6.30" x 4.67"

CliQ 24V 480W

DRP024V480W3AA

ATEX ClassIDiv2
Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

320-575 Vac

Dimensions

121 x 160 x 118.5 mm
4.76" x 6.30" x 4.67"

CliQ II 24V 480W

DRP024V480W3BA

Add to Comparison

Output Voltage

24V

Output Current

20A

Input Voltage

0-0 Vac

Dimensions

121 x 140 x 117.3 mm
4.76" x 5.51" x 4.62"
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy . ACCEPT