Temperature Power De-rating: Linear power derating from 100% load at 50°C to 50% load at 70°C with 2.5%/°C Line Power De-rating: < 120Vac de-rate power by 0.83% / Vac
運行濕度
5-95% RH (Non-Condensing)
衝擊測試(非運行狀態)
50 G, 11 ms, 3 shocks for each direction
振動測試(非運行狀態)
5-500 Hz, 2.09 Grms, 20 minute for each three axis
儲藏濕度
-
運行高度
Up to 5,000 meters (up to 16,400 feet or 106-54 kPa) ( 4000 meters for IEC 60335-1, IEC 61558-1 )
污染程度
2
碰撞試驗(運行狀態)
-
過壓類別
II
Corrosion
-
過壓保護
Main output 110-150% of rated normal voltage, Latch mode
超負載/過電保護
Main output 105-185% of rated current , Hiccup Mode
過溫保護
Latch Mode
短路保護
Hiccup Mode (Non-Latching, Auto-Recovery)
極性反接保護
-
防護等級
-
電擊防護等級
Class I & II
輸入端極性保護
-
電池極性保護
-
電池電壓保護錯誤
-
深度放電保護
-
超負載保護
-
過電保護
-
內部保險絲
-
Insufficient Input Voltage Protection
-
MTBF
700K hrs based on Telecordia SR-332
預計最長使用壽命
10 years
Safety Certificate
-
電氣安全
IEC60950-1 CB report IEC62368-1 CB report (Ed.2-2014 & Ed.3-2018) TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1
Home Appliance (for 12 V & 24 V model): IEC60335-1 CB report IEC61558-1 /-2-16 CB report TUV EN 60335-1 TUV EN 61558-1 /-2-16
CE
In conformance with EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014& EN 60601-1-2: 2015
醫療安全
IEC60601-1 CB report TUV EN60601-1 ANSI/AAMI ES 60601-1+CAN/CSA-C22.2 No.60601-1
In conformance with Electromagnetic Compatibility Regulations 2016 and Medical Devices Regulations 2002 Regulations 2016 (UK MDR 2002)
國家地區證書
-
BIS
-
KC
-
Electrical Equipment for Measurement, Control, and Laboratory Use
-
ITE Safety
IEC60950-1 CB report IEC62368-1 CB report TUV EN 62368-1 UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CCC GB 17625.1; GB 4943.1; GB/T 9254.1
SIL3
-
輻射與傳導
EN55032, CISPR 32 AS/NZS CISPR32 & CISPR11 Class B Compliance to EN55014-1, CISPR 14-1, AS/NZS CISPR 14 Class B Note: Class A Radiated Emission for Class II connection without earth connection