Click the link below to download the file.
Get your files as below link
Dowload link
24V
20W
0.833A
198-264 Vac
132 x 32 x 25.4 mm
5.20” x 1.26” x 1.00”
0.1 kg (0.22 lb) (0.22 lb)
· 24 V constant voltage built-in in luminaires design
· Wide operating temperature range
· Dry
and Damp location rated
·
Particular
in refrigeration display lighting application
·
Safety
certificated for household and refrigerator appliances
·
Suitable
for Class I and Class II systems
· 24 V constant voltage built-in in luminaires design
· Wide operating temperature range
· Dry
and Damp location rated
·
Particular
in refrigeration display lighting application
·
Safety
certificated for household and refrigerator appliances
·
Suitable
for Class I and Class II systems
24V
20W
0.833A
198-264 Vac
132 x 32 x 25.4 mm
5.20” x 1.26” x 1.00”
0.1 kg (0.22 lb) (0.22 lb)
Output Current
0.833A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
20W
|
Output Current Adjustment Range
0.1-0.833A
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
± 1%
|
Load Regulation
± 3%
|
PARD
-
|
Start-up Time
< 1.0s
|
Hold-up Time
-
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
-
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
< 50ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
220-240 Vac
|
Input Voltage Range
198-264 Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60 Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
0.20 typ.
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
85.4% typ. @ 230Vac
|
Max Inrush Current
>50% Duration
20A/ 150us |
Charging Time
-
|
Power Factor at 100% load
0.5 min.
|
Leakage Current
< 0.7mA @ 230Vac
|
Nominal Current
-
|
Total Harmonic Distortion
Meet IEC 61000-3-2 Class C
|
Max Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Metal sheet
|
|
Indicator
-
|
|
Cooling System
Convection
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
< 24dBA
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
Input Wire : Line: Black, Neutral: White, Wire Length 300mm
Output Wire: Positive: Red, Negative: Black, Wire Length 300mm |
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.1 kg (0.22 lb) (0.22 lb)
|
Dimensions
132 x 32 x
25.4 mm
5.20” x 1.26” x 1.00” |
Vibration (Operating)
-
|
Shock Test (Operating)
-
|
Operating Temperature
-40°C to +60°C
|
Storage Temperature
-40°C to +60°C
|
Power De-rating
-
|
Operating Humidity
10 to 90% RH (Non-Condensing)
|
Shock Test (Non-Operating)
-
|
Vibration (Non-Operating)
-
|
Storage Humidity
5 to 95% RH (Non-Condensing)
|
Operating Altitude
up to 5,000 m
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
Yes, Latch mode
|
Overload / Overcurrent
Yes, Latch mode
|
Over Temperature
Yes, Latch mode
|
Short Circuit
Yes, Latch mode
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
850,000 hrs. @ta: +45°C (as per Telcordia SR-332 , total failure rate less than 10% )
|
Expected Cap Life Time
50,000 hrs. at lifetime case temperature
|
Safety Certificate
-
|
Electrical Safety
CB scheme: IEC 61347-1, IEC 61347-2-13, IEC 60335-1, IEC 60335-2-89 and Annex BB, IEC 60335-2-24 and Annex CC, SELV Output
|
CE
In conformance with : Low Voltage Directive 2014/35/EU ; EMC Directive 2014/30/EU ; RoHS Directive 2011/65/EU+ (EU) 2015/863 and Erp Directive 2009/125/EC Implementing measure Commission Regulation (EU) 2019/2020.
|
Medical Safety
-
|
Galvanic Isolation
-
|
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
Input-Output: 1500 Vac
Output-Input: 1500Vac |
PE Resistance
-
|
UKCA
In conformance with : Elecrtical Equipment (Safety) Regulations 2016;
Electromagnetic Compatibility Regulations 2016 and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (as amended 2019,2020) |
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
-
|
SIL3
-
|
Emission
Compliance to BS EN/ EN 55015
|
Immunity
Compliance to BS EN/ EN 61547
|
Harmonic Current Emissions
EN 61000-3-2 Class C (230Vac @ 100% load)
|
Voltage Fluctuation and Flicker
IEC 61000-3-3 Pst ≤ 1.0; dmax ≤ 4% ; Plt ≤ 0.65 ; dc ≤ 3.3% ; Tmax ≤ 500ms
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
96W
4A
108-305 Vac
24V
80W
3.33A
108-305Vac
24V
60W
2.5A
108-305 Vac
24V
240W
10A
198-264Vac
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.